Loss of the Servo Motor 2 Signal on the THS Actuator for the SEC 1
TASK 27-94-00-810-838-A
Loss of the Servo Motor 2 Signal on the THS Actuator for the SEC 1
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 27-94-00-700-092-A
Subtask 27-94-00-810-087-A
[Rev.8 from Aug 2018]
2026.04.04 04:28:14 UTC
Loss of the Servo Motor 2 Signal on the THS Actuator for the SEC 1
1. Possible Causes
- SEC-1 [1CE1]
wiring of the K12-1 and 2 signal from the SEC 1 (1CE1) to the SEC 1 (1CE1) wiring of the K12-1B and 2B signal from the SEC 1 (1CE1) to the first terminal block
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 279412 | |
| AMM 27-94-34-000-001 | Removal of the SEC |
| AMM 27-94-34-400-001 | Installation of the SEC |
| AMM 27-96-00-710-022 | Operational Test of the THS Actuator Electrical Control (Activation for BITE Test) |
| AMM 27-96-00-740-001 | BITE Test of the EFCS (Ground Scanning) |
Subtask 27-94-00-700-092-A
A. Test
(1) Do the operational test of the THS actuator electrical control AMM 27-96-00-710-022.
4. Fault Isolation(1) Do the operational test of the THS actuator electrical control AMM 27-96-00-710-022.
NOTE: Do the ground setting only with the SEC 1.
(2) Do the BITE test of the EFCS (Ground Scanning) AMM 27-96-00-740-001. Subtask 27-94-00-810-087-A
A. If the BITE test gives the maintenance message:
SEC1 OR WIRING TO THS ACTR SERVO MOT2 9CE
(b) If there is continuity:
Subtask 27-94-00-700-093-A SEC1 OR WIRING TO THS ACTR SERVO MOT2 9CE
- replace the SEC-1 [1CE1] , AMM 27-94-34-000-001 and AMM 27-94-34-400-001.
- do a check of the
wiring of the K12-1 and 2 signal from the SEC 1 (1CE1) to the SEC 1 (1CE1) , ASM 279412.
(b) If there is continuity:
- do a check and repair the
wiring of the K12-1B and 2B signal from the SEC 1 (1CE1) to the first terminal block , ASM 279412.
B. Do the tests given in Para. 3.