Loss of the Servo Motor 2 Signal on the THS Actuator for the SEC 1


TASK 27-94-00-810-838-A
Loss of the Servo Motor 2 Signal on the THS Actuator for the SEC 1


1. Possible Causes
  • SEC-1 [1CE1]
  • wiring of the K12-1 and 2 signal from the SEC 1 (1CE1) to the SEC 1 (1CE1)
  • wiring of the K12-1B and 2B signal from the SEC 1 (1CE1) to the first terminal block
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 279412
AMM 27-94-34-000-001
Removal of the SEC
AMM 27-94-34-400-001
Installation of the SEC
AMM 27-96-00-710-022
Operational Test of the THS Actuator Electrical Control (Activation for BITE Test)
AMM 27-96-00-740-001
BITE Test of the EFCS (Ground Scanning)
3. Fault Confirmation
Subtask 27-94-00-700-092-A
A. Test
   (1) Do the operational test of the THS actuator electrical control AMM 27-96-00-710-022.
NOTE: Do the ground setting only with the SEC 1.
   (2) Do the BITE test of the EFCS (Ground Scanning) AMM 27-96-00-740-001.
4. Fault Isolation
Subtask 27-94-00-810-087-A
A. If the BITE test gives the maintenance message:
SEC1 OR WIRING TO THS ACTR SERVO MOT2 9CE
   (1) If the fault continues:
  • do a check of the wiring of the K12-1 and 2 signal from the SEC 1 (1CE1) to the SEC 1 (1CE1), ASM 279412.
     (a) If there is no continuity, repair the wiring.
     (b) If there is continuity:
  • do a check and repair the wiring of the K12-1B and 2B signal from the SEC 1 (1CE1) to the first terminal block, ASM 279412.
Subtask 27-94-00-700-093-A
B. Do the tests given in Para. 3.