Loss of the THS Command Transducer Signal for the SEC 1
TASK 27-94-00-810-836-A
Loss of the THS Command Transducer Signal for the SEC 1
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 27-94-00-700-088-A
Subtask 27-94-00-810-085-A
[Rev.8 from Aug 2018]
2026.04.04 04:28:14 UTC
Loss of the THS Command Transducer Signal for the SEC 1
1. Possible Causes
- SEC-1 [1CE1]
wiring from the ANI 2-3 XDCR COM signal of the SEC 1 (1CE1) to the first terminal block
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 27-90-00-810-817-A | Loss of the ACS1 Signal of the SEC1 COM Side |
| ASM 279412 | |
| AMM 27-94-34-000-001 | Removal of the SEC |
| AMM 27-94-34-400-001 | Installation of the SEC |
| AMM 27-96-00-710-022 | Operational Test of the THS Actuator Electrical Control (Activation for BITE Test) |
| AMM 27-96-00-740-001 | BITE Test of the EFCS (Ground Scanning) |
Subtask 27-94-00-700-088-A
A. Test
(1) Do the operational test of the THS actuator electrical control AMM 27-96-00-710-022.
(a) If the ground scanning gives the maintenance message:
SEC1 COM OR WIRING FROM THS ACTR XDCR2 9CE
SEC1 COM OR WIRING FROM THS ACTR XDCR2 9CE
SEC1 OR WIRING FROM L B ELEV POS XDCR 34CE3
SEC1 OR WIRING FROM R B ELEV POS XDCR 34CE4
4. Fault Isolation(1) Do the operational test of the THS actuator electrical control AMM 27-96-00-710-022.
NOTE: Do the ground setting only with the SEC 1.
(2) Do the BITE test of the EFCS (Ground Scanning) AMM 27-96-00-740-001. (a) If the ground scanning gives the maintenance message:
SEC1 COM OR WIRING FROM THS ACTR XDCR2 9CE
- refer to Para. Fault Isolation.
SEC1 COM OR WIRING FROM THS ACTR XDCR2 9CE
SEC1 OR WIRING FROM L B ELEV POS XDCR 34CE3
SEC1 OR WIRING FROM R B ELEV POS XDCR 34CE4
- do this trouble shooting procedure (Ref. TSM TASK 27-90-00-810-817).
Subtask 27-94-00-810-085-A
A. If the BITE test gives the maintenance message:
SEC1 COM OR WIRING FROM THS ACTR XDCR2 9CE
Subtask 27-94-00-700-089-A SEC1 COM OR WIRING FROM THS ACTR XDCR2 9CE
- replace the SEC-1 [1CE1] , AMM 27-94-34-000-001 and AMM 27-94-34-400-001.
- do a check and repair the
wiring from the ANI 2-3 XDCR COM signal of the SEC 1 (1CE1) to the first terminal block , ASM 279412.
B. Do the tests given in Para. 3.