W DOC AIRBUS | TSM A320F

Loss of the Accelerometer 4 Signal for the SEC 2


TASK 27-94-00-810-826-A
Loss of the Accelerometer 4 Signal for the SEC 2


1. Possible Causes
  • SEC-2 [1CE2]
  • ACCLRM-4 [12CE4]
  • wiring of the ANI 4-2 signal from the SEC 2 (1CE2) to the accelerometer 4 (12CE4)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 27-92-16-000-001
Removal of the Flight Control Accelerometer
AMM 27-92-16-400-001
Installation of the Flight Control Accelerometer
ASM 279224
AMM 27-94-34-000-001
Removal of the SEC
AMM 27-94-34-400-001
Installation of the SEC
AMM 27-96-00-740-001
BITE Test of the EFCS (Ground Scanning)
3. Fault Confirmation
Subtask 27-94-00-740-056-A
A. Test
   (1) Do the BITE test of the EFCS (ground scanning) AMM 27-96-00-740-001.
4. Fault Isolation
Subtask 27-94-00-810-075-B
A. If the BITE test gives the maintenance message:
SEC2 OR WIRING FROM ACCLRM4 12CE4
   (1) If the fault continues:
   (2) If the fault continues:
  • do a check and repair the wiring of the ANI 4-2 signal from the SEC 2 (1CE2) to the accelerometer 4 (12CE4) SEC 2 COM part and MON part ASM 279224.
Subtask 27-94-00-740-057-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:28:13 UTC