Loss of the Accelerometer 3 Signal for the SEC 2
TASK 27-94-00-810-825-A
Loss of the Accelerometer 3 Signal for the SEC 2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 27-94-00-740-054-A 4. Fault Isolation
Subtask 27-94-00-810-074-B
[Rev.8 from Aug 2018]
2026.04.04 04:28:13 UTC
Loss of the Accelerometer 3 Signal for the SEC 2
1. Possible Causes
- SEC-2 [1CE2]
- ACCLRM-3 [12CE3]
wiring of the ANI 4-1 signal from the SEC 2 (1CE2) to the accelerometer 3 (12CE3)
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 27-92-16-000-001 | Removal of the Flight Control Accelerometer |
| AMM 27-92-16-400-001 | Installation of the Flight Control Accelerometer |
| ASM 279224 | |
| AMM 27-94-34-000-001 | Removal of the SEC |
| AMM 27-94-34-400-001 | Installation of the SEC |
| AMM 27-96-00-740-001 | BITE Test of the EFCS (Ground Scanning) |
Subtask 27-94-00-740-054-A 4. Fault Isolation
Subtask 27-94-00-810-074-B
A. If the BITE test gives the maintenance message:
SEC2 OR WIRING FROM ACCLRM3 12CE3
Subtask 27-94-00-740-055-A SEC2 OR WIRING FROM ACCLRM3 12CE3
- replace the SEC-2 [1CE2] , AMM 27-94-34-000-001 and AMM 27-94-34-400-001.
- replace the ACCLRM-3 [12CE3] , AMM 27-92-16-000-001 and AMM 27-92-16-400-001.
- do a check and repair the
wiring of the ANI 4-1 signal from the SEC 2 (1CE2) to the accelerometer 3 (12CE3) SEC 2 COM part and MON part ASM 279224.
B. Do the test given in Para. 3.