W DOC AIRBUS | TSM A320F

Loss of the Accelerometer 2 Signal for the SEC 1


TASK 27-94-00-810-824-A
Loss of the Accelerometer 2 Signal for the SEC 1


1. Possible Causes
  • SEC-1 [1CE1]
  • ACCLRM-2 [12CE2]
  • wiring of the ANI 4-2 signal from the SEC 1 (1CE1) to the accelerometer 2 (12CE2)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 27-92-16-000-001
Removal of the Flight Control Accelerometer
AMM 27-92-16-400-001
Installation of the Flight Control Accelerometer
ASM 279224
AMM 27-94-34-000-001
Removal of the SEC
AMM 27-94-34-400-001
Installation of the SEC
AMM 27-96-00-740-001
BITE Test of the EFCS (Ground Scanning)
3. Fault Confirmation
Subtask 27-94-00-740-052-A
A. Test
   (1) Do the BITE test of the EFCS (ground scanning) AMM 27-96-00-740-001.
4. Fault Isolation
Subtask 27-94-00-810-073-B
A. If the BITE test gives the maintenance message:
SEC1 OR WIRING FROM ACCLRM2 12CE2
   (1) If the fault continues:
   (2) If the fault continues:
  • do a check and repair the wiring of the ANI 4-2 signal from the SEC 1 (1CE1) to the accelerometer 2 (12CE2) SEC 1 COM part and MON part ASM 279224.
Subtask 27-94-00-740-053-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:28:13 UTC