Loss of the Accelerometer 1 Signal for the SEC 1
TASK 27-94-00-810-823-A
Loss of the Accelerometer 1 Signal for the SEC 1
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 27-94-00-740-050-A 4. Fault Isolation
[Rev.8 from Aug 2018]
2026.04.04 04:28:13 UTC
Loss of the Accelerometer 1 Signal for the SEC 1
1. Possible Causes
- SEC-1 [1CE1]
- ACCLRM-1 [12CE1]
wiring of the ANI 4-1 signal from the SEC 1 (1CE1) to the accelerometer 1 (12CE1)
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 27-92-16-000-001 | Removal of the Flight Control Accelerometer |
| AMM 27-92-16-400-001 | Installation of the Flight Control Accelerometer |
| ASM 279224 | |
| AMM 27-94-34-000-001 | Removal of the SEC |
| AMM 27-94-34-400-001 | Installation of the SEC |
| AMM 27-96-00-740-001 | BITE Test of the EFCS (Ground Scanning) |
Subtask 27-94-00-740-050-A 4. Fault Isolation
NOTE: If the circuit breakers 15CE1 and 16CE1 are open for the aircraft dispatchin MMEL conditions (ELAC1 deactivated), it is not necessary to do the trouble-shooting procedure.
Subtask 27-94-00-810-072-B A. If the BITE test gives the maintenance message:
SEC1 OR WIRING FROM ACCLRM1 12CE1
Subtask 27-94-00-740-051-A SEC1 OR WIRING FROM ACCLRM1 12CE1
- replace the SEC-1 [1CE1] , AMM 27-94-34-000-001 and AMM 27-94-34-400-001.
- replace the ACCLRM-1 [12CE1] , AMM 27-92-16-000-001 and AMM 27-92-16-400-001.
- do a check and repair the
wiring of the ANI 4-1 signal from the SEC 1 (1CE1) to the accelerometer 1 (12CE1) SEC 1 COM part and MON part ASM 279224.
B. Do the test given in Para. 3.