Failure of the Roll Side Stick Transducer Unit Potentiometer (New-Generation Side-Stick Unit)
TASK 27-93-00-810-986-A
Failure of the Roll Side Stick Transducer Unit Potentiometer (New-Generation Side-Stick Unit)
A. Referenced Information
3. Fault Confirmation
Subtask 27-93-00-700-218-A
Subtask 27-93-00-810-271-A
[Rev.8 from Aug 2018]
2026.04.04 04:28:11 UTC
Failure of the Roll Side Stick Transducer Unit Potentiometer (New-Generation Side-Stick Unit)
NOTE: This task is applicable only for the new-generation side-stick unit.
1. Possible Causes- ELAC-1 [2CE1]
SSU-CAPT (100CE1) SSU-F/O (100CE2)
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 27-92-41-000-802 | Removal of the New-Generation Side-Stick Unit |
| AMM 27-92-41-400-802 | Installation of the New-Generation Side-Stick Unit |
| AMM 27-93-34-000-001 | Removal of the ELAC |
| AMM 27-93-34-400-001 | Installation of the ELAC |
Subtask 27-93-00-700-218-A
A. Test
Not applicable, you cannot confirm this fault on the ground.
4. Fault IsolationNot applicable, you cannot confirm this fault on the ground.
Subtask 27-93-00-810-271-A
A. If the post flight report gives the maintenance message:
ELAC1
ELAC1
- replace the ELAC-1 [2CE1] AMM 27-93-34-000-001 and AMM 27-93-34-400-001.
- during the subsequent flights, if this message is shown again, replace the
SSU-CAPT (100CE1) AMM 27-92-41-000-802 AMM 27-92-41-400-802 - during the subsequent flights, if this message is shown again, replace the
SSU-F/O (100CE2) AMM 27-92-41-000-802 AMM 27-92-41-400-802