Disagree of the Angle of Attack Sensors
TASK 27-93-00-810-963-A
Disagree of the Angle of Attack Sensors
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 27-93-00-700-187-A ** ON A/C NOT FOR ALL
Subtask 27-93-00-810-241-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:28:09 UTC
Disagree of the Angle of Attack Sensors
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 34-11-00-810-861-A | Different Angle of Attack Value on the three ADIRUs |
| AMM 34-11-19-000-001 | Removal of the Angle of Attack Sensor |
| AMM 34-11-19-400-001 | Installation of the Angle of Attack Sensor |
| AMM 34-13-00-200-001 | Visual Check of Pitot probes, Static ports, AOA and TAT sensors |
Subtask 27-93-00-700-187-A ** ON A/C NOT FOR ALL
A. Test
4. Fault Isolation- Not Applicable
Subtask 27-93-00-810-241-A ** ON A/C NOT FOR ALL
A. If one of these maintenance messages is shown:
AOA DATA DISAGREE
ELAC1 AOA DATA DISAGREE
ELAC2 AOA DATA DISAGREE
AOA DATA DISAGREE
ELAC1 AOA DATA DISAGREE
ELAC2 AOA DATA DISAGREE
- do a visual check of the SENSOR-ANGLE OF ATTACK, 1 [3FP1] SENSOR-ANGLE OF ATTACK, 2 [3FP2] SENSOR-ANGLE OF ATTACK, 3 [3FP3] AMM 34-13-00-200-001.
- replace the defective angle of attack sensor(s) AMM 34-11-19-000-001 AMM 34-11-19-400-001.
- do the trouble shooting procedure (Ref. TSM TASK 34-11-00-810-861).