W DOC AIRBUS | TSM A320F

Failure of the Angle of Attack Sensors 3


TASK 27-93-00-810-962-A
Failure of the Angle of Attack Sensors 3


1. Possible Causes
  • SENSOR-ANGLE OF ATTACK, 3 [3FP3]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 34-11-00-810-861-A
Different Angle of Attack Value on the three ADIRUs
AMM 34-11-19-000-001
Removal of the Angle of Attack Sensor
AMM 34-11-19-400-001
Installation of the Angle of Attack Sensor
3. Fault Confirmation
Subtask 27-93-00-700-186-A ** ON A/C NOT FOR ALL
A. Test
  • Not Applicable
4. Fault Isolation
Subtask 27-93-00-810-240-A ** ON A/C NOT FOR ALL
A. If the maintenance message AOA3 is shown:
   (1) Replace the SENSOR-ANGLE OF ATTACK, 3 [3FP3] AMM 34-11-19-000-001 and AMM 34-11-19-400-001.
   (2) Do the trouble shooting procedure (Ref. TSM TASK 34-11-00-810-861).
[Rev.8 from Aug 2018] 2026.04.04 04:28:09 UTC