Failure of the Angle of Attack Sensors 1
TASK 27-93-00-810-960-A
Failure of the Angle of Attack Sensors 1
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 27-93-00-700-184-A ** ON A/C NOT FOR ALL
Subtask 27-93-00-810-238-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:28:09 UTC
Failure of the Angle of Attack Sensors 1
1. Possible Causes
- SENSOR-ANGLE OF ATTACK, 1 [3FP1]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 34-11-00-810-861-A | Different Angle of Attack Value on the three ADIRUs |
| AMM 34-11-19-000-001 | Removal of the Angle of Attack Sensor |
| AMM 34-11-19-400-001 | Installation of the Angle of Attack Sensor |
Subtask 27-93-00-700-184-A ** ON A/C NOT FOR ALL
A. Test
Not Applicable
4. Fault IsolationNot Applicable
Subtask 27-93-00-810-238-A ** ON A/C NOT FOR ALL
A. If the maintenance message AOA1 is shown:
(1) Replace the SENSOR-ANGLE OF ATTACK, 1 [3FP1] AMM 34-11-19-000-001 and AMM 34-11-19-400-001.
(2) Do the trouble shooting procedure (Ref. TSM TASK 34-11-00-810-861).
(1) Replace the SENSOR-ANGLE OF ATTACK, 1 [3FP1] AMM 34-11-19-000-001 and AMM 34-11-19-400-001.
(2) Do the trouble shooting procedure (Ref. TSM TASK 34-11-00-810-861).