Incorrect Hydraulic Pressure Status Received by the FWC


TASK 27-93-00-810-948-A
Incorrect Hydraulic Pressure Status Received by the FWC


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 27-96-00-740-001
BITE Test of the EFCS (Ground Scanning)
AMM 29-10-00-200-008
Check Nitrogen Charge Pressure on Hydraulic Power Accumulators
ASM 293201
AMM 29-32-12-000-001
Removal of the System Pressure Switch
AMM 29-32-12-400-001
Installation of the System Pressure Switch
AMM 31-53-34-000-001
Removal of the Flight Warning Computer (FWC)
AMM 31-53-34-400-001
Installation of the Flight Warning Computer (FWC)
3. Fault Confirmation
Subtask 27-93-00-700-179-A
A. Test
   (1) Not applicable, the fault is evident.
4. Fault Isolation
Subtask 27-93-00-810-221-A
A. If the ELAC 1 FAULT and ELAC 2 FAULT warnings are shown on the upper ECAM display unit and if the FAULT legend on the ELAC 1 and ELAC 2 pushbutton switches is off:
   (1) If the test gives a maintenance message related to the Green or Blue hydraulic pressure switch with a F/CTL maintenance status:
  • do the trouble shooting procedure related to this maintenance message.
   (2) If the test does not give a maintenance message:
     (a) If the fault continues:
     (b) If the fault continues:
     (c) If the fault continues:
     (d) If the fault continues:
  • do a check of the wiring from the FWC 1 to the pressure switch 1151GN ASM 293201
  • do a check and repair the wiring from the FWC 1 to the pressure switch 2151GN.