Loss of the ELAC1 MON BUS 1 Signal for the SEC3
TASK 27-93-00-810-938-A
Loss of the ELAC1 MON BUS 1 Signal for the SEC3
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 27-93-00-740-192-A 4. Fault Isolation
Subtask 27-93-00-810-193-A
[Rev.8 from Aug 2018]
2026.04.04 04:28:07 UTC
Loss of the ELAC1 MON BUS 1 Signal for the SEC3
1. Possible Causes
wiring of the DGO 1 signal of the ELAC1 (2CE1) MON part wiring of the DSO 6 signal of the ELAC 1 (2CE1) COM part
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AWM 279231 | |
| ASM 279249 | |
| ASM 279250 | |
| AWM 279276 | |
| AMM 27-96-00-740-001 | BITE Test of the EFCS (Ground Scanning) |
Subtask 27-93-00-740-192-A 4. Fault Isolation
Subtask 27-93-00-810-193-A
A. If the test gives the maintenance message:
ELAC1 MON BUS1
(2) If the wiring is correct:
Subtask 27-93-00-740-193-A ELAC1 MON BUS1
- do a check of the
wiring of the DGO 1 signal of the ELAC1 (2CE1) MON part ASM 279250 from the terminal block 1837VT to the terminal block 213VT AWM 279231.
(2) If the wiring is correct:
- do a check and repair the
wiring of the DSO 6 signal of the ELAC 1 (2CE1) COM part ASM 279249 from the terminal block 1835VT to the terminal block 219VT AWM 279276.
B. Do the test given in Para. 3.