Loss of the YAW DAMPER Signal from the FAC 1/2 to the ELAC1
TASK 27-93-00-810-932-A
Loss of the YAW DAMPER Signal from the FAC 1/2 to the ELAC1
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 27-93-00-740-188-A 4. Fault Isolation
Subtask 27-93-00-810-181-A
[Rev.8 from Aug 2018]
2026.04.04 04:28:07 UTC
Loss of the YAW DAMPER Signal from the FAC 1/2 to the ELAC1
1. Possible Causes
- ELAC-1 [2CE1]
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 279237 | |
| AMM 27-93-34-000-001 | Removal of the ELAC |
| AMM 27-93-34-400-001 | Installation of the ELAC |
| AMM 27-96-00-740-001 | BITE Test of the EFCS (Ground Scanning) |
Subtask 27-93-00-740-188-A 4. Fault Isolation
Subtask 27-93-00-810-181-A
A. If the test gives the maintenance message ELAC1 OR WIRING FROM FAC 1/2:
Subtask 27-93-00-740-189-A - replace the ELAC-1 [2CE1] AMM 27-93-34-000-001 and AMM 27-93-34-400-001.
- do a check and repair the wiring
. from the ELAC1 (2CE1) pin AA/11E to the first terminal block
. from the ELAC1 (2CE1) pin AA/8E to the first terminal block
. from the ELAC1 (2CE1) pin AE/8H to the first terminal block
. from the ELAC1 (2CE1) pin AE/7K to the first terminal block ASM 279237.
B. Test
Do the test given in Para. 3.A.
Do the test given in Para. 3.A.