Loss of the Pitch Change Over Signal by the ELAC 2
TASK 27-93-00-810-930-A
Loss of the Pitch Change Over Signal by the ELAC 2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 27-93-00-740-184-A
Subtask 27-93-00-810-179-A
[Rev.8 from Aug 2018]
2026.04.04 04:28:07 UTC
Loss of the Pitch Change Over Signal by the ELAC 2
1. Possible Causes
- ELAC-2 [2CE2]
wiring of the PITCH AXIS OK (DSO 01) signal from the ELAC 2 COM part to the MON part (DSI 29) wiring of the PITCH AXIS OK (DSO 09) signal from the ELAC 2 COM part to the MON part (DSI 12) wiring of the PITCH AXIS OK (DSO 01) signal from the ELAC 2 MON part to the COM part (DSI 29) wiring of the PITCH AXIS OK (DSO 09) signal from the ELAC 2 MON part to the COM part (DSI 12)
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 31-32-00-810-932-A | Failure of the Discrete Links |
| ASM 279232 | |
| AMM 27-93-34-000-001 | Removal of the ELAC |
| AMM 27-93-34-400-001 | Installation of the ELAC |
| AMM 27-96-00-740-001 | BITE Test of the EFCS (Ground Scanning) |
Subtask 27-93-00-740-184-A
A. Test
(1) Check the PN of the FCDCs fitted on the aircraft:
(a) If the PN of the FCDCs is 115370-0105, you cannot confirm the fault, do the fault isolation.
(b) If the PN of the FCDCs is different from 115370-0105, do the BITE test of the EFCS (ground scanning) AMM 27-96-00-740-001.
4. Fault Isolation(1) Check the PN of the FCDCs fitted on the aircraft:
(a) If the PN of the FCDCs is 115370-0105, you cannot confirm the fault, do the fault isolation.
(b) If the PN of the FCDCs is different from 115370-0105, do the BITE test of the EFCS (ground scanning) AMM 27-96-00-740-001.
Subtask 27-93-00-810-179-A
A. If you cannot confirm the fault (FCDC PN 115370-0105) or if the BITE test gives the maintenance message CHECK PITCH CHANGE OVER WIRING OF ELAC2:
(a) Do the trouble shooting procedure (Ref. TSM TASK 31-32-00-810-932) related to the:
(a) Do a check of thewiring of the PITCH AXIS OK (DSO 01) signal from the ELAC 2 COM part to the MON part (DSI 29) ASM 279232.
wiring of the PITCH AXIS OK (DSO 09) signal from the ELAC 2 COM part to the MON part (DSI 12) ASM 279232.
wiring of the PITCH AXIS OK (DSO 01) signal from the ELAC 2 MON part to the COM part (DSI 29) ASM 279232.
wiring of the PITCH AXIS OK (DSO 09) signal from the ELAC 2 MON part to the COM part (DSI 12) ASM 279232.
Subtask 27-93-00-740-185-A - replace the ELAC-2 [2CE2] AMM 27-93-34-000-001 and AMM 27-93-34-400-001.
(a) Do the trouble shooting procedure (Ref. TSM TASK 31-32-00-810-932) related to the:
- PITCH AXIS OK (DSO 01) signal ELAC 2 COM part ASM 279232
- PITCH AXIS OK (DSO 09) signal ELAC 2 COM part ASM 279232
- PITCH AXIS OK (DSO 01) signal ELAC 2 MON part ASM 279232
- PITCH AXIS OK (DSO 09) signal ELAC 2 MON part ASM 279232
(a) Do a check of the
- if there is continuity, see Para. (b)
- if there is no continuity, repair the above wiring.
- if there is continuity, see Para. (c)
- if there is no continuity, repair the above wiring.
- if there is continuity, see Para. (d)
- if there is no continuity, repair the above wiring.
B. Do the test given in Para. 3.