Disagree between the Emergency Power Supply Discretes on the ELAC1 or ELAC2 or SEC1
TASK 27-93-00-810-920-A
Disagree between the Emergency Power Supply Discretes on the ELAC1 or ELAC2 or SEC1
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 27-93-00-860-078-A Subtask 27-93-00-865-050-A
Subtask 27-93-00-810-173-A
Subtask 27-93-00-860-079-A
[Rev.8 from Aug 2018]
2026.04.04 04:28:06 UTC
Disagree between the Emergency Power Supply Discretes on the ELAC1 or ELAC2 or SEC1
1. Possible Causes
- ELAC-1 [2CE1]
wiring of the LOSS OF NORMAL SPLY ON 2PP (DSI53) signal - SEC-1 [1CE1]
wiring of the SEC1 IN EMERGENCY PWR SPLY (DSI3) signal - ELAC-2 [2CE2]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 27-96-00-810-801-A | Result of the Operational Test of the Logics that Activates the ELAC 1&2 and SEC 1 STBY PWR SPLY not Satisfactory |
| ASM 279202 | |
| AMM 27-93-34-000-001 | Removal of the ELAC |
| AMM 27-93-34-400-001 | Installation of the ELAC |
| AMM 27-94-34-000-001 | Removal of the SEC |
| AMM 27-94-34-400-001 | Installation of the SEC |
| AMM 27-96-00-710-018 | Operational Test of Logics Activating ELAC 1&2, & SEC 1 STBY PWR SPLY & Ability of SEC 1&2 to Achieve Pitch CTL & Ability of Sidestick Priority Function |
| AMM 27-96-00-740-001 | BITE Test of the EFCS (Ground Scanning) |
| AMM 29-24-00-863-001 | Pressurize the Yellow Hydraulic System with the Electric Pump |
| AMM 29-24-00-864-001 | Depressurize the Yellow Hydraulic System |
Subtask 27-93-00-860-078-A Subtask 27-93-00-865-050-A
B. Table of the circuit breakers used in this procedure:
Subtask 27-93-00-700-160-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 121VU | FLIGHT CONTROLS/THS ACTR/MOT1 | 19CE1 | Q16 |
| 121VU | FLIGHT CONTROLS/ELAC2/NORM/SPLY | 15CE2 | R20 |
C. Test
(1) Open the circuit breakers FLT CTL/ELAC2/NORM/SPLY (15CE2) and FLT CTL/THS ACTR/MOT1 (19CE1).
(2) Do the BITE test of the EFCS (Ground Scanning) AMM 27-96-00-740-001.
(a) If the test confirms the fault:
1 Do the operational test AMM 27-96-00-710-018.
2 If the test gives a fault, do the trouble shooting procedure (Ref. TSM TASK 27-96-00-810-801).
4. Fault Isolation(1) Open the circuit breakers FLT CTL/ELAC2/NORM/SPLY (15CE2) and FLT CTL/THS ACTR/MOT1 (19CE1).
(2) Do the BITE test of the EFCS (Ground Scanning) AMM 27-96-00-740-001.
(a) If the test confirms the fault:
- Go to Para. 4. Fault Isolation.
1 Do the operational test AMM 27-96-00-710-018.
2 If the test gives a fault, do the trouble shooting procedure (Ref. TSM TASK 27-96-00-810-801).
Subtask 27-93-00-810-173-A
A. If the BITE test gives the maintenance message EMER DISCRETE DISAGREE:
(a) Replace the ELAC-1 [2CE1] AMM 27-93-34-000-001 and AMM 27-93-34-400-001.
(b) If the fault continues:
1 Replace the SEC-1 [1CE1] AMM 27-94-34-000-001 and AMM 27-94-34-400-001.
2 If the fault continues:
a Replace the ELAC-2 [2CE2] AMM 27-93-34-000-001 and AMM 27-93-34-400-001.
b If the fault continues:
a Do the operational test AMM 27-96-00-710-018.
b If the test gives a fault, do the trouble shooting procedure (Ref. TSM TASK 27-96-00-810-801).
Subtask 27-93-00-700-161-A - Do the test given in Para. 3. with the ELAC1 engaged only.
(a) Replace the ELAC-1 [2CE1] AMM 27-93-34-000-001 and AMM 27-93-34-400-001.
(b) If the fault continues:
- Do a check and repair the
wiring of the LOSS OF NORMAL SPLY ON 2PP (DSI53) signal from the ELAC1 (2CE1) COM part and MON part to the first terminal block ASM 279202.
- Do the test given in Para. 3. with the SEC1 engaged only.
1 Replace the SEC-1 [1CE1] AMM 27-94-34-000-001 and AMM 27-94-34-400-001.
2 If the fault continues:
- Do a check and repair the
wiring of the SEC1 IN EMERGENCY PWR SPLY (DSI3) signal from the SEC1 (1CE1) COM part and MON part to the first terminal block ASM 279202.
- Do the test given in Para. 3. with the ELAC2 engaged only.
a Replace the ELAC-2 [2CE2] AMM 27-93-34-000-001 and AMM 27-93-34-400-001.
b If the fault continues:
- Do a check and repair the
wiring of the LOSS OF NORMAL SPLY ON 2PP (DSI53) signal from the ELAC2 (2CE2) COM part and MON part to the first terminal block ASM 279202.
a Do the operational test AMM 27-96-00-710-018.
b If the test gives a fault, do the trouble shooting procedure (Ref. TSM TASK 27-96-00-810-801).
B. Do the test given in Para. 3.
5. Close-upSubtask 27-93-00-860-079-A
A. Put the aircraft back to its initial configuration.
(1) Depressurize the Yellow hydraulic system AMM 29-24-00-864-001.
(2) Close the circuit breakers FLT CTL/ELAC2/NORM/SPLY (15CE2) and FLT CTL/THS ACTR/MOT1 (19CE1).
(1) Depressurize the Yellow hydraulic system AMM 29-24-00-864-001.
(2) Close the circuit breakers FLT CTL/ELAC2/NORM/SPLY (15CE2) and FLT CTL/THS ACTR/MOT1 (19CE1).