Loss of the Pitch Change Over Signal by the SEC2
TASK 27-93-00-810-918-A
Loss of the Pitch Change Over Signal by the SEC2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 27-93-00-740-182-A 4. Fault Isolation
Subtask 27-93-00-810-170-A
[Rev.8 from Aug 2018]
2026.04.04 04:28:06 UTC
Loss of the Pitch Change Over Signal by the SEC2
1. Possible Causes
- SEC-2 [1CE2]
- SEC-1 [1CE1]
wiring of the PITCH NOT AVAIL IN ELAC2 (DSI10 and DSI26) signals wiring of the PITCH NOT AVAIL IN ELAC1 (DSI11 and DSI22) signals wiring of the L ELEV NOT AVAIL IN SEC1 (DSI13 and DSI27) signals wiring of the R ELEV NOT AVAIL IN SEC1 (DSI15 and DSI23) signals wiring of the L ELEV NOT AVAIL IN SEC2 (DSI05) signal wiring of the R ELEV NOT AVAIL IN SEC2 (DSI06) signal
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 31-32-00-810-932-A | Failure of the Discrete Links |
| ASM 279232 | |
| ASM 279233 | |
| ASM 279234 | |
| ASM 279235 | |
| AMM 27-94-34-000-001 | Removal of the SEC |
| AMM 27-94-34-400-001 | Installation of the SEC |
| AMM 27-96-00-740-001 | BITE Test of the EFCS (Ground Scanning) |
Subtask 27-93-00-740-182-A 4. Fault Isolation
Subtask 27-93-00-810-170-A
A. If the BITE test gives the maintenance message CHECK PITCH CHANGE OVER OF SEC2:
(a) replace the SEC-1 [1CE1] AMM 27-94-34-000-001 AMM 27-94-34-400-001.
(2) If the fault continues:
(a) do the trouble shooting procedure (Ref. TSM TASK 31-32-00-810-932) to the DSI 11 and DSI 22 discret input signal of the SEC 1 COM and MON ASM 279232.
(3) If the fault continues:
(a) Do a check of thewiring of the PITCH NOT AVAIL IN ELAC2 (DSI10 and DSI26) signals from the SEC2 (1CE2) COM part and MON part to the first terminal block ASM 279232:
wiring of the PITCH NOT AVAIL IN ELAC1 (DSI11 and DSI22) signals from the SEC2 (1CE2) COM part and MON part to the first terminal block ASM 279233:
wiring of the L ELEV NOT AVAIL IN SEC1 (DSI13 and DSI27) signals from the SEC2 (1CE2) COM part and MON part to the first terminal block ASM 279235:
wiring of the R ELEV NOT AVAIL IN SEC1 (DSI15 and DSI23) signals from the SEC2 (1CE2) COM part and MON part to the first terminal block ASM 279235:
wiring of the L ELEV NOT AVAIL IN SEC2 (DSI05) signal from the SEC2 (1CE2) COM part and MON part to the first terminal block ASM 279234:
wiring of the R ELEV NOT AVAIL IN SEC2 (DSI06) signal from the SEC2 (1CE2) COM part and MON part to the first terminal block ASM 279234.
Subtask 27-93-00-740-183-A - replace the SEC-2 [1CE2] AMM 27-94-34-000-001 and AMM 27-94-34-400-001.
(a) replace the SEC-1 [1CE1] AMM 27-94-34-000-001 AMM 27-94-34-400-001.
(2) If the fault continues:
(a) do the trouble shooting procedure (Ref. TSM TASK 31-32-00-810-932) to the DSI 11 and DSI 22 discret input signal of the SEC 1 COM and MON ASM 279232.
(3) If the fault continues:
(a) Do a check of the
- if there is continuity, see Para. (b)
- if there is no continuity, repair the above wiring.
- if there is continuity, see Para. (c)
- if there is no continuity, repair the above wiring.
- if there is continuity, see Para. (d)
- if there is no continuity, repair the above wiring.
- if there is continuity, see Para. (e)
- if there is no continuity, repair the above wiring.
- if there is continuity, see Para. (f)
- if there is no continuity, repair the above wiring.
B. Do the test given in Para. 3.