Loss of the FCDC 1 BUS 3 Signal for the ELAC 1
TASK 27-93-00-810-916-A
Loss of the FCDC 1 BUS 3 Signal for the ELAC 1
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 27-93-00-740-160-A 4. Fault Isolation
Subtask 27-93-00-810-154-A
[Rev.8 from Aug 2018]
2026.04.04 04:28:05 UTC
Loss of the FCDC 1 BUS 3 Signal for the ELAC 1
1. Possible Causes
- ELAC-1 [2CE1]
wiring of the DGI 12 signal from the ELAC 1 (2CE1) COM part to the first terminal block
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 27-93-34-000-001 | Removal of the ELAC |
| AMM 27-93-34-400-001 | Installation of the ELAC |
| ASM 279502 | |
| AMM 27-96-00-740-001 | BITE Test of the EFCS (Ground Scanning) |
Subtask 27-93-00-740-160-A 4. Fault Isolation
Subtask 27-93-00-810-154-A
A. If the BITE test gives the maintenance message:
ELAC1 MON OR BUS3 FROM FCDC1
Subtask 27-93-00-740-161-A ELAC1 MON OR BUS3 FROM FCDC1
- replace the ELAC-1 [2CE1] AMM 27-93-34-000-001 and AMM 27-93-34-400-001.
- do a check and repair the
wiring of the DGI 12 signal from the ELAC 1 (2CE1) COM part to the first terminal block ASM 279502.
B. Do the test given in Para. 3.