W DOC AIRBUS | TSM A320F

Loss of the FCDC 1 BUS 6 Signal for the ELAC 2


TASK 27-93-00-810-914-A
Loss of the FCDC 1 BUS 6 Signal for the ELAC 2


1. Possible Causes
  • ELAC-2 [2CE2]
  • FCDC-1 [3CE1]
  • wiring of the DGI 12 signal from the ELAC 2 (2CE2) MON part to the FCDC 1 (3CE1)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 27-93-34-000-001
Removal of the ELAC
AMM 27-93-34-400-001
Installation of the ELAC
ASM 279502
AMM 27-95-34-000-001
Removal of the FCDC
AMM 27-95-34-400-001
Installation of the FCDC
AMM 27-96-00-740-001
BITE Test of the EFCS (Ground Scanning)
3. Fault Confirmation
Subtask 27-93-00-740-156-A
A. Test
   (1) Do the BITE test of the EFCS (ground scanning) AMM 27-96-00-740-001.
4. Fault Isolation
Subtask 27-93-00-810-152-A
A. If the BITE test gives the maintenance message:
ELAC2-MON OR BUS 6 FROM FCDC1
   (1) Replace the ELAC-2 [2CE2] AMM 27-93-34-000-001 and AMM 27-93-34-400-001.
   (2) If the fault continues:
   (3) If the fault continues:
  • Do a check and repair the wiring of the DGI 12 signal from the ELAC 2 (2CE2) MON part to the FCDC 1 (3CE1) ASM 279502.
Subtask 27-93-00-740-157-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:28:05 UTC