Loss of the FCDC 2 BUS 4 Signal for the ELAC 1
TASK 27-93-00-810-913-A
Loss of the FCDC 2 BUS 4 Signal for the ELAC 1
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 27-93-00-740-154-A 4. Fault Isolation
Subtask 27-93-00-810-151-A
[Rev.8 from Aug 2018]
2026.04.04 04:28:05 UTC
Loss of the FCDC 2 BUS 4 Signal for the ELAC 1
1. Possible Causes
- ELAC-1 [2CE1]
- FCDC-2 [3CE2]
wiring of the DGI 12 signal from the ELAC 1 (2CE1) MON part to the FCDC 2(3CE2)
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 27-93-34-000-001 | Removal of the ELAC |
| AMM 27-93-34-400-001 | Installation of the ELAC |
| ASM 279503 | |
| AMM 27-95-34-000-001 | Removal of the FCDC |
| AMM 27-95-34-400-001 | Installation of the FCDC |
| AMM 27-96-00-740-001 | BITE Test of the EFCS (Ground Scanning) |
Subtask 27-93-00-740-154-A 4. Fault Isolation
Subtask 27-93-00-810-151-A
A. If the BITE test gives the maintenance message:
ELAC1-MON OR BUS 4 FROM FCDC2
(1) Replace the ELAC-1 [2CE1] AMM 27-93-34-000-001 and AMM 27-93-34-400-001.
(2) If the fault continues:
Subtask 27-93-00-740-155-A ELAC1-MON OR BUS 4 FROM FCDC2
(1) Replace the ELAC-1 [2CE1] AMM 27-93-34-000-001 and AMM 27-93-34-400-001.
(2) If the fault continues:
- Replace the FCDC-2 [3CE2] AMM 27-95-34-000-001 and AMM 27-95-34-400-001.
- Do a check and repair the
wiring of the DGI 12 signal from the ELAC 1 (2CE1) MON part to the FCDC 2(3CE2) ASM 279503.
B. Do the test given in Para. 3.