Loss of the BUS 2 Signal of the ELAC 2 detected by FCDCs
TASK 27-93-00-810-907-A
Loss of the BUS 2 Signal of the ELAC 2 detected by FCDCs
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 27-93-00-740-142-A 4. Fault Isolation
Subtask 27-93-00-810-145-A
[Rev.8 from Aug 2018]
2026.04.04 04:28:05 UTC
Loss of the BUS 2 Signal of the ELAC 2 detected by FCDCs
1. Possible Causes
- ELAC-2 [2CE2]
wiring of the DGO 02 signal from the ELAC 2 (2CE2) to the first terminal block
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 31-32-00-810-934-A | Failure of the Digital Links |
| ASM 279252 | |
| AMM 27-93-34-000-001 | Removal of the ELAC |
| AMM 27-93-34-400-001 | Installation of the ELAC |
| AMM 27-96-00-740-001 | BITE Test of the EFCS (Ground Scanning) |
Subtask 27-93-00-740-142-A 4. Fault Isolation
Subtask 27-93-00-810-145-A
A. If the BITE test gives the maintenance message:
ELAC2 COM BUS2
or
ELAC2 MON BUS2
Subtask 27-93-00-740-143-A ELAC2 COM BUS2
or
ELAC2 MON BUS2
- Replace the ELAC-2 [2CE2] , AMM 27-93-34-000-001 and AMM 27-93-34-400-001.
- Do the trouble shooting procedure (Ref. TSM TASK 31-32-00-810-934) to the DGO 02 digital output signal of the ELAC 2 COM and MON ASM 279252.
- Do a check and repair the
wiring of the DGO 02 signal from the ELAC 2 (2CE2) to the first terminal block , COM or MON part as shown in the maintenance message ASM 279252.
B. Do the test given in Para. 3.