W DOC AIRBUS | TSM A320F

Loss of Pin Programming Inputs Signal for the ELAC2


TASK 27-93-00-810-903-A
Loss of Pin Programming Inputs Signal for the ELAC2


1. Possible Causes
  • ELAC-2 [2CE2]
  • wiring of the PIN PROGRAM ELAC2 signal
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 279240
AMM 27-93-34-000-001
Removal of the ELAC
AMM 27-93-34-400-001
Installation of the ELAC
AMM 27-96-00-740-001
BITE Test of the EFCS (Ground Scanning)
3. Fault Confirmation
Subtask 27-93-00-740-168-A
A. Test
   (1) Do the BITE test of the EFCS (ground scanning) AMM 27-96-00-740-001.
4. Fault Isolation
Subtask 27-93-00-810-158-A
A. If the BITE test gives the maintenance message:
ELAC2 SDI INPUTS
   (1) If the fault continues:
  • do a check and repair the wiring of the PIN PROGRAM ELAC2 signal from the ELAC2 (2CE2) COM and MON part to the ground terminal ASM 279240.
5. Close-up
Subtask 27-93-00-740-169-A
A. Do the test given in Para. 3.