Loss of the SFCC 1 Signal for the ELAC 2
TASK 27-93-00-810-892-A
Loss of the SFCC 1 Signal for the ELAC 2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 27-93-00-740-126-A 4. Fault Isolation
Subtask 27-93-00-810-137-B
[Rev.8 from Aug 2018]
2026.04.04 04:28:02 UTC
Loss of the SFCC 1 Signal for the ELAC 2
1. Possible Causes
- ELAC-2 [2CE2]
wiring of the DGI 11 signal from the ELAC 2 (2CE2) to the first terminal block wiring of the SLATS RETRACTED (DSI 26) signal from the ELAC 2 (2CE2) to the SFCC 1 (21CV) wiring of the GND signal (pin 9H) from the SFCC 1 (21CV) to the ground
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 27-51-00-810-839-A | EFCS Identifies a Loss of Data from the SFCC-1 (2) |
| ASM 279242 | |
| ASM 279252 | |
| AMM 27-93-34-000-001 | Removal of the ELAC |
| AMM 27-93-34-400-001 | Installation of the ELAC |
| AMM 27-96-00-740-001 | BITE Test of the EFCS (Ground Scanning) |
Subtask 27-93-00-740-126-A 4. Fault Isolation
Subtask 27-93-00-810-137-B
A. If the BITE test gives the maintenance message:
ELAC2 OR WIRING FROM SFCC1
(a) Do a check and repair thewiring of the DGI 11 signal from the ELAC 2 (2CE2) to the first terminal block , COM part only ASM 279252.
(b) Do a check and repair thewiring of the SLATS RETRACTED (DSI 26) signal from the ELAC 2 (2CE2) to the SFCC 1 (21CV) ASM 279242.
(c) Do a check and repair thewiring of the GND signal (pin 9H) from the SFCC 1 (21CV) to the ground ASM 279242.
(d) Do this trouble shooting procedure (Ref. TSM TASK 27-51-00-810-839).
Subtask 27-93-00-740-127-A ELAC2 OR WIRING FROM SFCC1
- replace the ELAC-2 [2CE2] AMM 27-93-34-000-001 and AMM 27-93-34-400-001.
(a) Do a check and repair the
(b) Do a check and repair the
(c) Do a check and repair the
(d) Do this trouble shooting procedure (Ref. TSM TASK 27-51-00-810-839).
B. Do the test given in Para. 3.