Failure of the Right Blue Elevator Servocontrol Actuator Solenoid Valve
TASK 27-93-00-810-876-A
Failure of the Right Blue Elevator Servocontrol Actuator Solenoid Valve
A. Referenced Information
3. Fault Confirmation
Subtask 27-93-00-700-166-A
Subtask 27-93-00-810-176-A
[Rev.8 from Aug 2018]
2026.04.04 04:28:00 UTC
Failure of the Right Blue Elevator Servocontrol Actuator Solenoid Valve
CAUTION:
DO NOT SWAP FLIGHT CONTROL COMPUTERS. IF THERE IS A SHORT CIRCUIT, YOU WILL CAUSE DAMAGE TO A SERVICEABLE COMPUTER WHEN YOU SWAP THEM.
1. Possible Causes- RELAY-THS MOT 3 INHIBITION 1 [51CE]
- RELAY-THS MOT 3 INHIBITION 2 [52CE]
- ELAC-2 [2CE2]
- solenoid valve of the servocontrol 34CE4
- SERVO CTL-R ELEVATOR, OUTBD B [34CE4]
wiring of the SOL VLV1 signal from the servocontrol (34CE4) to the ELAC2 (2CE2) wiring from the ELAC2 (2CE2) COM part to the ELAC2 COM part wiring from the ELAC2 (2CE2) COM part to the ELAC2 MON part wiring from the ELAC2 (2CE2) MON part pins AE/13B and AE/12C to the first terminal block
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 27-34-51-000-001 | Removal of the Elevator Servo Control |
| AMM 27-34-51-000-005 | Removal of the Solenoid Valve of the Elevator Servo-Control Actuator |
| AMM 27-34-51-400-001 | Installation of the Elevator Servo Control |
| AMM 27-34-51-400-004 | Installation of the Solenoid Valve of the Elevator Servo-Control Actuator |
| AIPC 27920803 | |
| ASM 279308 | |
| AMM 27-93-34-000-001 | Removal of the ELAC |
| AMM 27-93-34-400-001 | Installation of the ELAC |
| AMM 27-96-00-710-020 | Operational Test of the Side Stick Assembly (Activation for the BITE Test) |
| AMM 27-96-00-740-001 | BITE Test of the EFCS (Ground Scanning) |
Subtask 27-93-00-700-166-A
A. Test
(1) Do the operational test of the side stick assembly (Activation for the BITE test) AMM 27-96-00-710-020.
(2) Do the BITE test of the EFCS (Ground Scanning) AMM 27-96-00-740-001.
4. Fault Isolation(1) Do the operational test of the side stick assembly (Activation for the BITE test) AMM 27-96-00-710-020.
(2) Do the BITE test of the EFCS (Ground Scanning) AMM 27-96-00-740-001.
Subtask 27-93-00-810-176-A
A. If the tests give the maintenance message R B ELEV MODE VLV 34CE4:
(1) Remove the RELAY-THS MOT 3 INHIBITION 1 [51CE] and RELAY-THS MOT 3 INHIBITION 2 [52CE] AIPC 27920803.
(2) Do a check of the resistance and insulation of the relays.
(c) If the resistance is between 280 and 400 ohms and if the insulation is more than 500 KOhms:
(4) Remove the ELAC2 AMM 27-93-34-000-001.
(5) At the ELAC2 receptacle, do a check of the resistance between the pin AB/14K and the pin AE/14B ASM 279308.
a Replace the solenoid valve of the servocontrol 34CE4 AMM 27-34-51-000-005 and AMM 27-34-51-400-004.
b Do again a check of the resistance of the solenoid valve between the pin C/K and the pin C/L of the outboard elevator servocontrol (34CE4) (40 to 100 ohms).
a Repair thewiring of the SOL VLV1 signal from the servocontrol (34CE4) to the ELAC2 (2CE2) , from the pin C/K to the pin AB/14K and from the pin C/L to the pin AE/14B ASM 279308.
b Replace the ELAC-2 [2CE2] AMM 27-93-34-000-001 and AMM 27-93-34-400-001.
(b) If the resistance is more than 100 ohms:
a Replace the solenoid valve of the servocontrol 34CE4 AMM 27-34-51-000-005 and AMM 27-34-51-400-004.
b Do again a check of the resistance of the solenoid valve between the pin C/K and the pin C/L of the outboard elevator servocontrol (34CE4) (40 to 100 ohms).
a Repair thewiring of the SOL VLV1 signal from the servocontrol (34CE4) to the ELAC2 (2CE2) , from the pin C/K to the pin AB/14K and from the pin C/L to the pin AE/14B ASM 279308.
b Install the ELAC2 AMM 27-93-34-400-001.
(c) If the resistance values are in the specified limits:
Replace the solenoid valve AMM 27-34-51-000-005 and AMM 27-34-51-400-004.
2 If the fault continues:
Replace the SERVO CTL-R ELEVATOR, OUTBD B [34CE4] AMM 27-34-51-000-001 and AMM 27-34-51-400-001.
3 Do a check of thewiring from the ELAC2 (2CE2) COM part to the ELAC2 COM part , from the pin AB/13K to the pin AB/13F ASM 279308:
a If the wiring is correct, see Para. 4_.
b If the wiring is not correct:
wiring from the ELAC2 (2CE2) COM part to the ELAC2 MON part , from the pin AB/13E to the pin AE/12D ASM 279308:
a If the wiring is correct, see Para. 5_.
b If the wiring is not correct:
wiring from the ELAC2 (2CE2) MON part pins AE/13B and AE/12C to the first terminal block ASM 279308.
6 Install the ELAC-2 [2CE2] AMM 27-93-34-400-001.
(b) If the resistance is less than 100 Megohms:
If the resistance is less than 100 Megohms:
. Replace the SERVO CTL-R ELEVATOR, OUTBD B [34CE4] AMM 27-34-51-000-001 and AMM 27-34-51-400-001.
. Replace the ELAC-2 [2CE2] AMM 27-93-34-000-001 and AMM 27-93-34-400-001.
2 If the resistance is more than 100 Megohms:
a Repair the wiring of the solenoid valve signal from the SERVO CTL-R ELEVATOR, OUTBD B [34CE4] to the ELAC-2 [2CE2] .
b Replace the ELAC-2 [2CE2] AMM 27-93-34-000-001 and AMM 27-93-34-400-001.
Subtask 27-93-00-700-167-A (1) Remove the RELAY-THS MOT 3 INHIBITION 1 [51CE] and RELAY-THS MOT 3 INHIBITION 2 [52CE] AIPC 27920803.
(2) Do a check of the resistance and insulation of the relays.
NOTE: The resistance of the winding (pins X1 and X2) must be between 280 and 400 ohms; the insulation must be more than 500 KOhms.
(a) If the resistance is less than 280 ohms: - Replace the RELAY-THS MOT 3 INHIBITION 1 [51CE] and/or RELAY-THS MOT 3 INHIBITION 2 [52CE] AIPC 27920803.
- Replace the ELAC-2 [2CE2] AMM 27-93-34-000-001 and AMM 27-93-34-400-001.
(c) If the resistance is between 280 and 400 ohms and if the insulation is more than 500 KOhms:
- Install the RELAY-THS MOT 3 INHIBITION 1 [51CE] and RELAY-THS MOT 3 INHIBITION 2 [52CE] .
- See Para (3).
(4) Remove the ELAC2 AMM 27-93-34-000-001.
(5) At the ELAC2 receptacle, do a check of the resistance between the pin AB/14K and the pin AE/14B ASM 279308.
NOTE: The resistance must be between 40 and 100 ohms.
(a) If the resistance is less than 40 ohms: - At the outboard elevator servocontrol (34CE4), do a check of the resistance of the solenoid valve between the pin C/K and the pin C/L ASM 279308.
NOTE: The resistance must be between 40 and 100 ohms.
1 If the resistance values are out of the specified limits:a Replace the solenoid valve of the servocontrol 34CE4 AMM 27-34-51-000-005 and AMM 27-34-51-400-004.
b Do again a check of the resistance of the solenoid valve between the pin C/K and the pin C/L of the outboard elevator servocontrol (34CE4) (40 to 100 ohms).
- If the resistance values are out of the specified limits:
. Replace the SERVO CTL-R ELEVATOR, OUTBD B [34CE4] AMM 27-34-51-000-001 and AMM 27-34-51-400-001.
. Replace the ELAC-2 [2CE2] AMM 27-93-34-000-001 and AMM 27-93-34-400-001. - If the resistance values are in the specified limits:
Replace the ELAC-2 [2CE2] AMM 27-93-34-000-001 and AMM 27-93-34-400-001.
a Repair the
b Replace the ELAC-2 [2CE2] AMM 27-93-34-000-001 and AMM 27-93-34-400-001.
(b) If the resistance is more than 100 ohms:
- At the outboard elevator servocontrol (34CE4), do a check of the resistance of the solenoid valve between the pin C/K and the pin C/L ASM 279308.
NOTE: The resistance must be between 40 and 100 ohms.
1 If the resistance values are out of the specified limits:a Replace the solenoid valve of the servocontrol 34CE4 AMM 27-34-51-000-005 and AMM 27-34-51-400-004.
b Do again a check of the resistance of the solenoid valve between the pin C/K and the pin C/L of the outboard elevator servocontrol (34CE4) (40 to 100 ohms).
- If the resistance values are out of the specified limits:
. Replace the SERVO CTL-R ELEVATOR, OUTBD B [34CE4] AMM 27-34-51-000-001 and AMM 27-34-51-400-001.
. Install the ELAC2 AMM 27-93-34-400-001. - If the resistance values are in the specified limits:
Install the ELAC2 AMM 27-93-34-400-001.
a Repair the
b Install the ELAC2 AMM 27-93-34-400-001.
(c) If the resistance values are in the specified limits:
- See Para.(6).
NOTE: The resistance must be more than 100 Megohms.
(a) If the resistance is more than 100 Megohms: - Replace the ELAC-2 [2CE2] AMM 27-93-34-000-001 and AMM 27-93-34-400-001.
Replace the solenoid valve AMM 27-34-51-000-005 and AMM 27-34-51-400-004.
2 If the fault continues:
Replace the SERVO CTL-R ELEVATOR, OUTBD B [34CE4] AMM 27-34-51-000-001 and AMM 27-34-51-400-001.
3 Do a check of the
a If the wiring is correct, see Para. 4_.
b If the wiring is not correct:
- Repair it.
- Install the ELAC2 AMM 27-93-34-400-001.
a If the wiring is correct, see Para. 5_.
b If the wiring is not correct:
- Repair it.
- Install the ELAC2 AMM 27-93-34-400-001.
6 Install the ELAC-2 [2CE2] AMM 27-93-34-400-001.
(b) If the resistance is less than 100 Megohms:
- At the SERVO CTL-R ELEVATOR, OUTBD B [34CE4] , do a check of the insulation of the solenoid valve between pin C/K (pin C/L) and the ground.
- Replace the solenoid valve AMM 27-34-51-000-005 and AMM 27-34-51-400-004.
If the resistance is less than 100 Megohms:
. Replace the SERVO CTL-R ELEVATOR, OUTBD B [34CE4] AMM 27-34-51-000-001 and AMM 27-34-51-400-001.
. Replace the ELAC-2 [2CE2] AMM 27-93-34-000-001 and AMM 27-93-34-400-001.
2 If the resistance is more than 100 Megohms:
a Repair the wiring of the solenoid valve signal from the SERVO CTL-R ELEVATOR, OUTBD B [34CE4] to the ELAC-2 [2CE2] .
b Replace the ELAC-2 [2CE2] AMM 27-93-34-000-001 and AMM 27-93-34-400-001.
B. Do the test given in Para. 3.