W DOC AIRBUS | TSM A320F

Loss of the Signal of the Right Blue Elevator-Servocontrol Servovalve by the ELAC 1


TASK 27-93-00-810-873-A
Loss of the Signal of the Right Blue Elevator-Servocontrol Servovalve by the ELAC 1


1. Possible Causes
  • servovalve
  • ELAC-1 [2CE1]
  • wiring of the R ELEV SV (ANO 2) signal from the ELAC 1 (2CE1) COM part, pins AB/2J, 2H to the ELAC 1 COM part, pins AA/3H, 3G
  • wiring from the ELAC 1 (2CE1) COM part to the MON part
  • wiring from the ELAC 1 (2CE1) MON part, pins AD/3D, 4D to the first terminal block
  • wiring of the LVDT SV SPLY signal
  • wiring of the LVDT POS (ANI 3-2) signal
  • SERVO CTL-R ELEVATOR, OUTBD B [34CE4]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 27-34-51-000-001
Removal of the Elevator Servo Control
AMM 27-34-51-000-008
Removal of the Elevator Servo Control Actuator Servo Valve
AMM 27-34-51-400-001
Installation of the Elevator Servo Control
AMM 27-34-51-400-003
Installation of the Elevator Servo Control Actuator Servo Valve
ASM 279307
AMM 27-93-34-000-001
Removal of the ELAC
AMM 27-93-34-400-001
Installation of the ELAC
AMM 27-96-00-710-020
Operational Test of the Side Stick Assembly (Activation for the BITE Test)
AMM 27-96-00-740-001
BITE Test of the EFCS (Ground Scanning)
3. Fault Confirmation
Subtask 27-93-00-700-130-A
A. Test
   (1) Do the operational test of the side stick assembly (activation for the BITE test) AMM 27-96-00-710-020.
   (2) Do the BITE test of the EFCS (ground scanning) AMM 27-96-00-740-001.
4. Fault Isolation
Subtask 27-93-00-810-120-A
A. If the test gives the maintenance message:
ELAC1 COM OR WIRING TO R B ELEV SERVO VLV 34CE4
   (1) If the fault continues:
   (2) If the fault continues:
     (a) Do a check of the wiring of the R ELEV SV (ANO 2) signal from the ELAC 1 (2CE1) COM part, pins AB/2J, 2H to the ELAC 1 COM part, pins AA/3H, 3G ASM 279307:
  • if there is continuity see Para. (b)
  • if there is no continuity repair the above wiring.
     (b) Do a check of the wiring from the ELAC 1 (2CE1) COM part to the MON part from pins AA/3J, 3K to pins AD/3B, 4B ASM 279307:
  • if there is continuity see Para. (c)
  • if there is no continuity repair the above wiring.
     (c) Do a check of the wiring from the ELAC 1 (2CE1) MON part, pins AD/3D, 4D to the first terminal block ASM 279307.
  • if there is continuity see Para. (d)
  • if there is no continuity repair the above wiring.
     (d) Do a check of the wiring of the LVDT SV SPLY signal , from the servocontrol (34CE4) to the first terminal block ASM 279307.
  • if there is continuity see Para. (e)
  • if there is no continuity repair the above wiring.
     (e) Do a check of the wiring of the LVDT POS (ANI 3-2) signal, from the ELAC 1 (2CE1) MON part to the servocontrol (34CE4) ASM 279307.
  • if there is continuity see Para. (3)
  • if there is no continuity repair the above wiring.
   (3) Replace the SERVO CTL-R ELEVATOR, OUTBD B [34CE4] AMM 27-34-51-000-001 and AMM 27-34-51-400-001.
Subtask 27-93-00-700-131-A
B. Do the tests given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:28:00 UTC