W DOC AIRBUS | TSM A320F

Loss of the IR 2 BUS 3 for the ELAC 1


TASK 27-93-00-810-854-A
Loss of the IR 2 BUS 3 for the ELAC 1


1. Possible Causes
  • ELAC-1 [2CE1]
  • wiring of the DGI 03 signal from the ELAC 1 (2CE1) to the first terminal block
  • ADIRU-2 [1FP2]
  • wiring of the INERTIAL REFERENCE OUTPUT BUS 3 from the ADIRU2 (1FP2) to the first terminal block
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 31-32-00-810-934-A
Failure of the Digital Links
ASM 279250
AMM 27-93-34-000-001
Removal of the ELAC
AMM 27-93-34-400-001
Installation of the ELAC
AMM 27-96-00-740-001
BITE Test of the EFCS (Ground Scanning)
AMM 34-12-34-000-001
Removal of the ADIRU
AMM 34-12-34-400-001
Installation of the ADIRU
3. Fault Confirmation
Subtask 27-93-00-740-102-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the BITE test of the EFCS (ground scanning) AMM 27-96-00-740-001.
Subtask 27-93-00-740-102-B ** ON A/C NOT FOR ALL
A. Test
   (1) Do a check of the Post Flight Report (PFR)
If the IR2 OR BUS3 TO ELAC1 maintenance message is shown in flight phase 08 (PH08):
     (a) On the overhead panel, on the FLT CTL panel 23VU: release, then push the FLT CTL/ELAC1 pushbutton switch.
     (b) Make an entry in the logbook to monitor the aircraft during the subsequent flight.
     (c) During the subsequent flight:
  • If the fault occurs again, continue the trouble shooting procedure.
   (2) Do the BITE test of the EFCS (ground scanning) AMM 27-96-00-740-001.
4. Fault Isolation
Subtask 27-93-00-810-103-A
A. If the BITE test gives the maintenance message:
IR2 OR BUS3 TO ELAC1
and on the upper ECAM DU, the INOP SYS CAT 3 DUAL warning does not come into view:
   (1) If the fault continues:
  • do a check and repair the wiring of the DGI 03 signal from the ELAC 1 (2CE1) to the first terminal block, MON part only ASM 279250.
Subtask 27-93-00-810-196-A
B. If the BITE test gives the maintenance message:
IR2 or BUS3 to ELAC1
and on the upper ECAM DU, the INOP SYS CAT 3 DUAL warning comes into view:
   (1) If the fault continues:
     (a) Remove the ADIRU2.
     (b) Do a check of the wiring of the INERTIAL REFERENCE OUTPUT BUS 3 from the ADIRU2 (1FP2) to the first terminal block.
       1 If there is no continuity:
         a Repair it.
         b Install the ADIRU2.
       2 If there is continuity:
         a Install the ADIRU2.
         b Do the trouble shooting procedure that follows (Ref. TSM TASK 31-32-00-810-934).
Subtask 27-93-00-740-103-A
C. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:27:58 UTC