Loss of the IR 2 BUS 3 for the ELAC 1
TASK 27-93-00-810-854-A
Loss of the IR 2 BUS 3 for the ELAC 1
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 27-93-00-740-102-A ** ON A/C NOT FOR ALL Subtask 27-93-00-740-102-B ** ON A/C NOT FOR ALL
Subtask 27-93-00-810-103-A
[Rev.8 from Aug 2018]
2026.04.04 04:27:58 UTC
Loss of the IR 2 BUS 3 for the ELAC 1
1. Possible Causes
- ELAC-1 [2CE1]
wiring of the DGI 03 signal from the ELAC 1 (2CE1) to the first terminal block - ADIRU-2 [1FP2]
wiring of the INERTIAL REFERENCE OUTPUT BUS 3 from the ADIRU2 (1FP2) to the first terminal block
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 31-32-00-810-934-A | Failure of the Digital Links |
| ASM 279250 | |
| AMM 27-93-34-000-001 | Removal of the ELAC |
| AMM 27-93-34-400-001 | Installation of the ELAC |
| AMM 27-96-00-740-001 | BITE Test of the EFCS (Ground Scanning) |
| AMM 34-12-34-000-001 | Removal of the ADIRU |
| AMM 34-12-34-400-001 | Installation of the ADIRU |
Subtask 27-93-00-740-102-A ** ON A/C NOT FOR ALL Subtask 27-93-00-740-102-B ** ON A/C NOT FOR ALL
A. Test
(1) Do a check of the Post Flight Report (PFR)
If the IR2 OR BUS3 TO ELAC1 maintenance message is shown in flight phase 08 (PH08):
(a) On the overhead panel, on the FLT CTL panel 23VU: release, then push the FLT CTL/ELAC1 pushbutton switch.
(b) Make an entry in the logbook to monitor the aircraft during the subsequent flight.
(c) During the subsequent flight:
4. Fault Isolation(1) Do a check of the Post Flight Report (PFR)
If the IR2 OR BUS3 TO ELAC1 maintenance message is shown in flight phase 08 (PH08):
(a) On the overhead panel, on the FLT CTL panel 23VU: release, then push the FLT CTL/ELAC1 pushbutton switch.
(b) Make an entry in the logbook to monitor the aircraft during the subsequent flight.
(c) During the subsequent flight:
- If the fault occurs again, continue the trouble shooting procedure.
Subtask 27-93-00-810-103-A
A. If the BITE test gives the maintenance message:
IR2 OR BUS3 TO ELAC1
and on the upper ECAM DU, the INOP SYS CAT 3 DUAL warning does not come into view:
Subtask 27-93-00-810-196-A IR2 OR BUS3 TO ELAC1
and on the upper ECAM DU, the INOP SYS CAT 3 DUAL warning does not come into view:
- replace the ELAC-1 [2CE1] AMM 27-93-34-000-001 and AMM 27-93-34-400-001.
- do a check and repair the
wiring of the DGI 03 signal from the ELAC 1 (2CE1) to the first terminal block , MON part only ASM 279250.
B. If the BITE test gives the maintenance message:
IR2 or BUS3 to ELAC1
and on the upper ECAM DU, the INOP SYS CAT 3 DUAL warning comes into view:
(a) Remove the ADIRU2.
(b) Do a check of thewiring of the INERTIAL REFERENCE OUTPUT BUS 3 from the ADIRU2 (1FP2) to the first terminal block .
1 If there is no continuity:
a Repair it.
b Install the ADIRU2.
2 If there is continuity:
a Install the ADIRU2.
b Do the trouble shooting procedure that follows (Ref. TSM TASK 31-32-00-810-934).
Subtask 27-93-00-740-103-A IR2 or BUS3 to ELAC1
and on the upper ECAM DU, the INOP SYS CAT 3 DUAL warning comes into view:
- replace the ADIRU-2 [1FP2] AMM 34-12-34-000-001 and AMM 34-12-34-400-001.
(a) Remove the ADIRU2.
(b) Do a check of the
1 If there is no continuity:
a Repair it.
b Install the ADIRU2.
2 If there is continuity:
a Install the ADIRU2.
b Do the trouble shooting procedure that follows (Ref. TSM TASK 31-32-00-810-934).
C. Do the test given in Para. 3.