Loss of the ADR 3 BUS 3 for the ELAC 1
TASK 27-93-00-810-850-A
Loss of the ADR 3 BUS 3 for the ELAC 1
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 27-93-00-740-094-A 4. Fault Isolation
Subtask 27-93-00-810-099-A
[Rev.8 from Aug 2018]
2026.04.04 04:27:58 UTC
Loss of the ADR 3 BUS 3 for the ELAC 1
1. Possible Causes
- ELAC-1 [2CE1]
wiring of the DGI 07 signal from the ELAC 1 (2CE1) to the first terminal block
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 34-11-00-810-861-A | Different Angle of Attack Value on the three ADIRUs |
| TSM TASK 34-13-00-810-998-A | Altitude or Airspeed Discrepancy between CAPT PFD - F/O PFD - STDBY/ISIS |
| TSM TASK 34-13-00-810-998-B | Altitude or Airspeed Disagree between the CAPT PFD or F/O PFD and Standby Horizon Indicator or ISIS (Aircraft with RVSM capability on the three ADIRUs) |
| ASM 279250 | |
| AMM 27-93-34-000-001 | Removal of the ELAC |
| AMM 27-93-34-400-001 | Installation of the ELAC |
| AMM 27-96-00-740-001 | BITE Test of the EFCS (Ground Scanning) |
Subtask 27-93-00-740-094-A 4. Fault Isolation
Subtask 27-93-00-810-099-A
A. If the BITE test gives the maintenance message:
ELAC1 COM OR BUS3 FROM ADR3
(b) Different Angle of Attack Value on the three ADIRUs (Ref. TSM TASK 34-11-00-810-861).
Subtask 27-93-00-740-095-A ELAC1 COM OR BUS3 FROM ADR3
- replace the ELAC-1 [2CE1] AMM 27-93-34-000-001 and AMM 27-93-34-400-001.
- do a check and repair the
wiring of the DGI 07 signal from the ELAC 1 (2CE1) to the first terminal block , COM part only ASM 279250.
- do the following trouble shooting procedures.
(b) Different Angle of Attack Value on the three ADIRUs (Ref. TSM TASK 34-11-00-810-861).
B. Do the test given in Para. 3.