Failure of the THS Actuator Servo Motor 2


TASK 27-93-00-810-842-A
Failure of the THS Actuator Servo Motor 2


1. Possible Causes
  • pitch trim actuator
  • wiring of the command signal from the THS actuator (9CE) to the first terminal block
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 27-44-57-000-001
Removal of the Pitch Trim Actuator from the THS Actuator
AMM 27-44-57-400-001
Installation of the Pitch Trim Actuator to the THS Actuator
ASM 279312
AMM 27-96-00-710-022
Operational Test of the THS Actuator Electrical Control (Activation for BITE Test)
AMM 27-96-00-740-001
BITE Test of the EFCS (Ground Scanning)
3. Fault Confirmation
Subtask 27-93-00-700-096-A
A. Test
   (1) Do the operational test of the THS actuator electrical control AMM 27-96-00-710-022.
NOTE: Do the ground setting only with the ELAC 1.
   (2) Do the BITE test of the EFCS (ground scanning) AMM 27-96-00-740-001.
4. Fault Isolation
Subtask 27-93-00-810-091-A
A. If the BITE test gives the maintenance message:
THS ACTR SERVO MOT2 9CE
   (1) If the fault continues:
  • do a check and repair the wiring of the command signal from the THS actuator (9CE) to the first terminal block, ASM 279312.
Subtask 27-93-00-700-097-A
B. Do the tests given in Para. 3.