Failure of the THS Actuator Servo Motor 2
TASK 27-93-00-810-842-A
Failure of the THS Actuator Servo Motor 2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 27-93-00-700-096-A
Subtask 27-93-00-810-091-A
[Rev.8 from Aug 2018]
2026.04.04 04:27:58 UTC
Failure of the THS Actuator Servo Motor 2
1. Possible Causes
- pitch trim actuator
wiring of the command signal from the THS actuator (9CE) to the first terminal block
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 27-44-57-000-001 | Removal of the Pitch Trim Actuator from the THS Actuator |
| AMM 27-44-57-400-001 | Installation of the Pitch Trim Actuator to the THS Actuator |
| ASM 279312 | |
| AMM 27-96-00-710-022 | Operational Test of the THS Actuator Electrical Control (Activation for BITE Test) |
| AMM 27-96-00-740-001 | BITE Test of the EFCS (Ground Scanning) |
Subtask 27-93-00-700-096-A
A. Test
(1) Do the operational test of the THS actuator electrical control AMM 27-96-00-710-022.
4. Fault Isolation(1) Do the operational test of the THS actuator electrical control AMM 27-96-00-710-022.
NOTE: Do the ground setting only with the ELAC 1.
(2) Do the BITE test of the EFCS (ground scanning) AMM 27-96-00-740-001. Subtask 27-93-00-810-091-A
A. If the BITE test gives the maintenance message:
THS ACTR SERVO MOT2 9CE
Subtask 27-93-00-700-097-A THS ACTR SERVO MOT2 9CE
- replace the pitch trim actuator , AMM 27-44-57-000-001 and AMM 27-44-57-400-001.
- do a check and repair the
wiring of the command signal from the THS actuator (9CE) to the first terminal block , ASM 279312.
B. Do the tests given in Para. 3.