Failure of the THS Actuator Servo Motor 1


TASK 27-93-00-810-837-A
Failure of the THS Actuator Servo Motor 1


1. Possible Causes
  • RELAY-PITCH TRIM ACTUATOR MOTOR 1 SPLY [36CE1]
  • ELAC-2 [2CE2]
  • Electronic module 1
  • wiring of the K3-1 signal from the ELAC 2 (2CE2) to the first terminal block
  • wiring of the DSI-49 signal from the ELAC 2 (2CE2) to the ELAC 2 (2CE2)
  • wiring of the enable signal from the THS actuator (9CE) to the ELAC 2 (2CE2)
  • wiring of the enable signal from the THS actuator (9CE) to the ground
  • wiring from the relay (36CE1) to the ELAC 2 (2CE2) and to the THS actuator (9CE)
  • wiring of the fault signal from the THS actuator to the ELAC 2 (2CE2)
  • pitch trim actuator
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 24-41-00-861-002
Energize the Aircraft Electrical Circuits from the External Power
AMM 27-44-57-000-001
Removal of the Pitch Trim Actuator from the THS Actuator
AMM 27-44-57-000-002
Removal of the Electronic Modules of the Pitch Trim Actuator
AMM 27-44-57-400-001
Installation of the Pitch Trim Actuator to the THS Actuator
AMM 27-44-57-400-002
Installation of the Electronic Modules of the Pitch Trim Actuator
AIPC 27920803
ASM 279313
AMM 27-93-34-000-001
Removal of the ELAC
AMM 27-93-34-400-001
Installation of the ELAC
AMM 27-96-00-740-001
BITE Test of the EFCS (Ground Scanning)
AMM 29-10-00-864-001
Depressurize the Green Hydraulic System
AMM 29-10-00-864-002
Depressurize the Yellow Hydraulic System
AMM 29-10-00-864-003
Depressurize the Blue Hydraulic System
3. Fault Confirmation
Subtask 27-93-00-700-086-A
A. Test
   (1) Energize the aircraft electrical circuits
AMM 24-41-00-861-002.
   (2) Make sure that the Green, Blue and Yellow hydraulic systems are not pressurized AMM 29-10-00-864-001, AMM 29-10-00-864-003 and AMM 29-10-00-864-002.
   (3) On the panel 24VU:
  • release the FLT CTL/ELAC2 pushbutton switch.(On this pushbutton switch, the OFF legend comes on).
   (4) Wait 30 seconds.
   (5) On the panel 24VU:
  • push the FLT CTL/ELAC2 pushbutton switch.(On this pushbutton switch, the OFF legend goes off).
   (6) Do the BITE test of the EFCS (ground scanning) AMM 27-96-00-740-001.
NOTE: Wait 60 seconds before you start the BITE test.
4. Fault Isolation
Subtask 27-93-00-810-086-A
A. If the BITE test gives the maintenance message:
THS ACTR SERVO MOT1 9CE
   (1) Remove the RELAY-PITCH TRIM ACTUATOR MOTOR 1 SPLY [36CE1] AIPC 27920803.
   (2) Do a check of the resistance between pins X1 and X2 of the relay ASM 279313 .
     (a) If the resistance is less than 280 ohms:
     (b) If the resistance is more than 400 ohms:
  • replace the RELAY-PITCH TRIM ACTUATOR MOTOR 1 SPLY [36CE1] .
     (c) If the resistance is between 280 and 400 ohms:
  • install the RELAY-PITCH TRIM ACTUATOR MOTOR 1 SPLY [36CE1]
  • go to Para (3).
   (3) If the fault continues:
   (4) If the fault continues:
   (5) If the fault continues:
   (6) If the fault continues:
  • do a check of the wiring of the K3-1 signal from the ELAC 2 (2CE2) to the first terminal block, COM part and MON part ASM 279313.
     (a) If there is no continuity:
  • repair the wiring.
     (b) If there is continuity:
  • continue the trouble shooting.
   (7) If the fault continues:
  • do a check of the wiring of the DSI-49 signal from the ELAC 2 (2CE2) to the ELAC 2 (2CE2) COM part and MON part ASM 279313.
     (a) If there is no continuity:
  • repair the wiring.
     (b) If there is continuity:
  • continue the trouble shooting.
   (8) If the fault continues:
  • do a check of the wiring of the enable signal from the THS actuator (9CE) to the ELAC 2 (2CE2) ASM 279313.
     (a) If there is no continuity:
  • repair the wiring.
     (b) If there is continuity:
  • continue the trouble shooting.
   (9) If the fault continues:
  • do a check of the wiring of the enable signal from the THS actuator (9CE) to the ground ASM 279313.
     (a) If there is no continuity:
  • repair the wiring.
     (b) If there is continuity:
  • continue the trouble shooting.
   (10) If the fault continues:
  • do a check of the wiring from the relay (36CE1) to the ELAC 2 (2CE2) and to the THS actuator (9CE) and the wiring of the fault signal from the THS actuator to the ELAC 2 (2CE2) ASM 279313.
     (a) If there is no continuity:
  • repair the wiring.
     (b) If there is continuity:
  • continue the trouble shooting.
   (11) If the fault continues:
     (a) Replace the pitch trim actuator AMM 27-44-57-000-001 AMM 27-44-57-400-001.
Subtask 27-93-00-700-087-A
B. Do the tests given in Para. 3.