W DOC AIRBUS | TSM A320F

Loss of the Servo Motor 1 Signal on the THS Actuator for ELAC2


TASK 27-93-00-810-835-A
Loss of the Servo Motor 1 Signal on the THS Actuator for ELAC2


1. Possible Causes
  • ELAC-2 [2CE2]
  • pitch trim actuator
  • wiring of the ANO 3 signal from ELAC2 (2CE2) to ELAC2 (2CE2)
  • wiring of the command signal from the THS actuator (9CE) to ELAC2 (2CE2)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 27-44-57-000-001
Removal of the Pitch Trim Actuator from the THS Actuator
AMM 27-44-57-400-001
Installation of the Pitch Trim Actuator to the THS Actuator
ASM 279313
AMM 27-93-34-000-001
Removal of the ELAC
AMM 27-93-34-400-001
Installation of the ELAC
AMM 27-96-00-710-022
Operational Test of the THS Actuator Electrical Control (Activation for BITE Test)
AMM 27-96-00-740-001
BITE Test of the EFCS (Ground Scanning)
3. Fault Confirmation
Subtask 27-93-00-700-082-A
A. Test
   (1) Do the operational test of the THS-actuator electrical control AMM 27-96-00-710-022.
NOTE: It is necessary to do the ground setting only with ELAC2.
   (2) Do the BITE test of the EFCS (ground scanning) AMM 27-96-00-740-001.
4. Fault Isolation
Subtask 27-93-00-810-084-A
A. If the BITE test gives the maintenance message:
ELAC 2 OR OUTPUT TO THS ACTR SERVO MOT 1 9CE
   (1) If the fault continues:
   (2) If the fault continues:
  • Do a check of the wiring of the ANO 3 signal from ELAC2 (2CE2) to ELAC2 (2CE2), ASM 279313.
     (a) If there is no continuity, repair the wiring.
     (b) If there is continuity:
  • Do a check and repair the wiring of the command signal from the THS actuator (9CE) to ELAC2 (2CE2), ASM 279313.
Subtask 27-93-00-700-083-A
B. Do the tests given in Para. 3.