Loss of the Yellow Hydraulic Pressure Transducer Signal for the ELAC 2
TASK 27-93-00-810-830-A
Loss of the Yellow Hydraulic Pressure Transducer Signal for the ELAC 2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 27-93-00-860-072-A Subtask 27-93-00-740-080-A
Subtask 27-93-00-810-079-B
Subtask 27-93-00-860-073-A
[Rev.8 from Aug 2018]
2026.04.04 04:27:57 UTC
Loss of the Yellow Hydraulic Pressure Transducer Signal for the ELAC 2
1. Possible Causes
- ELAC-2 [2CE2]
wiring of the ANI 4-5 signal from the ELAC 2 (2CE2) COM and MON parts to the first terminal block
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 279228 | |
| AMM 27-93-34-000-001 | Removal of the ELAC |
| AMM 27-93-34-400-001 | Installation of the ELAC |
| AMM 27-96-00-740-001 | BITE Test of the EFCS (Ground Scanning) |
| AMM 29-10-00-863-002 | Pressurize the Yellow Hydraulic System with a Hydraulic Ground Power-Cart |
| AMM 29-10-00-864-002 | Depressurize the Yellow Hydraulic System |
Subtask 27-93-00-860-072-A Subtask 27-93-00-740-080-A
B. Test
(1) Do the BITE test of the EFCS (Ground Scanning) AMM 27-96-00-740-001.
(a) If the test gives a maintenance message, do the step 4. Fault Isolation.
(b) If there is no maintenance message:
1 No other maintenance action is necessary.
2 If the fault history report shows that the same failure occurred more than three times, replace the ELAC-2 [2CE2] .
4. Fault Isolation(1) Do the BITE test of the EFCS (Ground Scanning) AMM 27-96-00-740-001.
(a) If the test gives a maintenance message, do the step 4. Fault Isolation.
(b) If there is no maintenance message:
1 No other maintenance action is necessary.
2 If the fault history report shows that the same failure occurred more than three times, replace the ELAC-2 [2CE2] .
Subtask 27-93-00-810-079-B
A. If the BITE test gives the maintenance message:
ELAC2 OR WIRING FROM Y HYD PRESS XMTR 3065GN
Subtask 27-93-00-740-081-A ELAC2 OR WIRING FROM Y HYD PRESS XMTR 3065GN
- replace the ELAC-2 [2CE2] , AMM 27-93-34-000-001 and AMM 27-93-34-400-001.
- do a check and repair the
wiring of the ANI 4-5 signal from the ELAC 2 (2CE2) COM and MON parts to the first terminal block , ASM 279228.
B. Do the test given in Para. 3.
5. Close-upSubtask 27-93-00-860-073-A