Loss of the FCDC DGI 10 Bus
TASK 27-92-00-810-835-A
Loss of the FCDC DGI 10 Bus
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 27-92-00-740-116-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 27-92-00-810-091-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:27:55 UTC
Loss of the FCDC DGI 10 Bus
1. Possible Causes
- wiring of the DGI 10 signal from the FCDC to the first terminal block
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 27-95-34-000-001 | Removal of the FCDC |
| AMM 27-95-34-400-001 | Installation of the FCDC |
| AMM 27-96-00-740-001 | BITE Test of the EFCS (Ground Scanning) |
Subtask 27-92-00-740-116-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 27-92-00-810-091-A ** ON A/C NOT FOR ALL
A. If the test confirm the fault:
Subtask 27-92-00-740-117-A ** ON A/C NOT FOR ALL - replace the FCDC (3CE1 or 3CE2) related to the maintenance message AMM 27-95-34-000-001 and AMM 27-95-34-400-001.
- do a check of the wiring of the DGI 10 signal from the FCDC to the first terminal block related to the maintenance message.
B. Do the test given in Para. 3.