W DOC AIRBUS | TSM A320F

Failure of the Yellow Hydraulic Pressure Switch


TASK 27-92-00-810-828-A
Failure of the Yellow Hydraulic Pressure Switch


1. Possible Causes
  • SEC-2 [1CE2]
  • SEC-3 [1CE3]
  • ELAC-1 [2CE1]
  • ELAC-2 [2CE2]
  • SYSTEM-PRESS-SW [3151GN]
  • wiring from the pressure switch (3151GN) pins A/A and A/B
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 31-32-00-810-932-A
Failure of the Discrete Links
ASM 279227
AMM 27-93-34-000-001
Removal of the ELAC
AMM 27-93-34-400-001
Installation of the ELAC
AMM 27-94-34-000-001
Removal of the SEC
AMM 27-94-34-400-001
Installation of the SEC
AMM 27-96-00-740-001
BITE Test of the EFCS (Ground Scanning)
AMM 29-10-00-863-002
Pressurize the Yellow Hydraulic System with a Hydraulic Ground Power-Cart
AMM 29-10-00-864-002
Depressurize the Yellow Hydraulic System
AMM 29-32-12-000-003
Removal of the System Pressure Switch
AMM 29-32-12-400-003
Installation of the System Pressure Switch
3. Fault Confirmation
Subtask 27-92-00-860-064-A
A. Job Set-Up
   (1) Pressurize the Yellow hydraulic system AMM 29-10-00-863-002.
Subtask 27-92-00-865-059-A
B. Table of the circuit breakers used in this procedure:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUFLIGHT CONTROLS/FCDC1/SPLY20CE1B10
121VUFLIGHT CONTROLS/FCDC2/SPLY20CE2Q20
Subtask 27-92-00-740-100-A
C. Test
   (1) Do the BITE test of the EFCS (Ground Scanning) AMM 27-96-00-740-001.
4. Fault Isolation
Subtask 27-92-00-810-077-A
A. If the BITE test gives the maintenance message:
Y HYD PRESS SW2
  • do the trouble shooting procedure (Ref. TSM TASK 31-32-00-810-932)
    . related to the DSI 19 discrete input signal of the SEC 2 and SEC 3,
    . related to the DSI 32 discrete input signal of the ELAC 1 MON and ELAC 2 MON ASM 279227.
  • open and close the circuit breakers 20CE1 and 20CE2.
If you do not find faults during the trouble shooting procedure (Ref. TSM TASK 31-32-00-810-932), go to Para. (5).
   (1) If the fault continues:
   (2) If the fault continues:
   (3) If the fault continues:
   (4) If the fault continues:
   (5) If the fault continues:
     (a) If the fault continues:
  • do a check and repair the wiring from the pressure switch (3151GN) pins A/A and A/B to the ground, SEC2, SEC3, ELAC1 and ELAC2 ASM 279227.
  • open and close the circuit breakers 20CE1 and 20CE2.
Subtask 27-92-00-740-101-A
B. Do the BITE test given in Para. 3.
5. Close-up
Subtask 27-92-00-860-065-A
A. Depressurize the Yellow hydraulic system AMM 29-10-00-864-002.
[Rev.8 from Aug 2018] 2026.04.04 04:39:23 UTC