W DOC AIRBUS | TSM A320F

Failure of the Green Hydraulic Pressure Transducer


TASK 27-92-00-810-826-A
Failure of the Green Hydraulic Pressure Transducer


1. Possible Causes
  • HYDR. PRESSURE TRANSMITTER [1065GN]
  • wiring of the 28VDC signal from the pressure transducer (1065GN) to the first terminal block
  • wiring of the DC SIGNAL from the pressure transducer (1065GN) to the first terminal block
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 31-32-00-810-933-A
Failure of the Analog Links
ASM 279228
AMM 27-96-00-740-001
BITE Test of the EFCS (Ground Scanning)
AMM 29-10-00-863-001
Pressurize the Green Hydraulic System with a Hydraulic Ground Power-Cart
AMM 29-10-00-864-001
Depressurize the Green Hydraulic System
AMM 29-32-11-000-001
Removal of the Hydraulic Pressure Transducer
AMM 29-32-11-400-001
Installation of the Hydraulic Pressure Transducer
3. Fault Confirmation
Subtask 27-92-00-860-060-A
A. Job Set-Up
   (1) Pressurize the Green hydraulic system AMM 29-10-00-863-001.
Subtask 27-92-00-740-096-A
B. Test
   (1) Do the BITE test of the EFCS (Ground Scanning) AMM 27-96-00-740-001.
4. Fault Isolation
Subtask 27-92-00-810-075-A
A. If the BITE test gives the maintenance messages:
G HYD PRESS XMTR 1065GN
with
SDAC1 G HYD PRESS XMTR 1065GN
or
SDAC2 G HYD PRESS XMTR 1065GN
   (1) If the fault continues:
   (2) If the fault continues:
  • do a check and repair the wiring of the 28VDC signal from the pressure transducer (1065GN) to the first terminal block, ASM 279228.
   (3) If the fault continues:
  • do a check and repair the wiring of the DC SIGNAL from the pressure transducer (1065GN) to the first terminal block, ASM 279228.
Subtask 27-92-00-740-097-A
B. Do the BITE test given in Para. 3.
5. Close-up
Subtask 27-92-00-860-061-A
A. Depressurize the Green hydraulic system AMM 29-10-00-864-001.
[Rev.8 from Aug 2018] 2026.04.04 04:27:54 UTC