Failure of the Accelerometers 3 and 4
TASK 27-92-00-810-807-A
Failure of the Accelerometers 3 and 4
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 27-92-00-740-058-A 4. Fault Isolation
Subtask 27-92-00-810-056-A
[Rev.8 from Aug 2018]
2026.04.04 04:27:54 UTC
Failure of the Accelerometers 3 and 4
1. Possible Causes
- ACCLRM-3 [12CE3]
- ACCLRM-4 [12CE4]
wiring of the power supply signal from the accelerometer (12CE3) to the first terminal block wiring of the power supply signal from the accelerometer (12CE4) to the first terminal block
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 27-92-16-000-001 | Removal of the Flight Control Accelerometer |
| AMM 27-92-16-400-001 | Installation of the Flight Control Accelerometer |
| ASM 279224 | |
| AMM 27-96-00-740-001 | BITE Test of the EFCS (Ground Scanning) |
Subtask 27-92-00-740-058-A 4. Fault Isolation
Subtask 27-92-00-810-056-A
A. If the BITE test gives the maintenance messages:
ACCLRM 3 12CE3
ACCLRM 4 12CE4
Subtask 27-92-00-740-059-A ACCLRM 3 12CE3
ACCLRM 4 12CE4
- replace the ACCLRM-3 [12CE3] and the ACCLRM-4 [12CE4] , AMM 27-92-16-000-001 and AMM 27-92-16-400-001.
- do a check and repair the
wiring of the power supply signal from the accelerometer (12CE3) to the first terminal block and thewiring of the power supply signal from the accelerometer (12CE4) to the first terminal block , ASM 279224.
B. Do the test given in Para. 3.