W DOC AIRBUS | TSM A320F

Failure of the Accelerometers 3 and 4


TASK 27-92-00-810-807-A
Failure of the Accelerometers 3 and 4


1. Possible Causes
  • ACCLRM-3 [12CE3]
  • ACCLRM-4 [12CE4]
  • wiring of the power supply signal from the accelerometer (12CE3) to the first terminal block
  • wiring of the power supply signal from the accelerometer (12CE4) to the first terminal block
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 27-92-16-000-001
Removal of the Flight Control Accelerometer
AMM 27-92-16-400-001
Installation of the Flight Control Accelerometer
ASM 279224
AMM 27-96-00-740-001
BITE Test of the EFCS (Ground Scanning)
3. Fault Confirmation
Subtask 27-92-00-740-058-A
A. Test
   (1) Do the BITE test of the EFCS (ground scanning) AMM 27-96-00-740-001.
4. Fault Isolation
Subtask 27-92-00-810-056-A
A. If the BITE test gives the maintenance messages:
ACCLRM 3 12CE3
ACCLRM 4 12CE4
   (1) If the fault continues:
  • do a check and repair the wiring of the power supply signal from the accelerometer (12CE3) to the first terminal block and the wiring of the power supply signal from the accelerometer (12CE4) to the first terminal block, ASM 279224.
Subtask 27-92-00-740-059-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:27:54 UTC