W DOC AIRBUS | TSM A320F

Failure of the Accelerometer 4


TASK 27-92-00-810-806-A
Failure of the Accelerometer 4


1. Possible Causes
  • ACCLRM-4 [12CE4]
  • wiring of the power supply signal from the accelerometer 4 (12CE4) to the first terminal block
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 27-92-16-000-001
Removal of the Flight Control Accelerometer
AMM 27-92-16-400-001
Installation of the Flight Control Accelerometer
ASM 279224
AMM 27-96-00-740-001
BITE Test of the EFCS (Ground Scanning)
3. Fault Confirmation
Subtask 27-92-00-740-056-A
A. Test
   (1) Do the BITE test of the EFCS (ground scanning) AMM 27-96-00-740-001.
4. Fault Isolation
Subtask 27-92-00-810-055-A
A. If the BITE test gives the maintenance message:
ACCLRM 4 12CE4
   (1) If the fault continues:
  • do a check and repair the wiring of the power supply signal from the accelerometer 4 (12CE4) to the first terminal block, ASM 279224.
Subtask 27-92-00-740-057-A
B. Do the test given in Para. 3.