Failure of the Accelerometer 4
TASK 27-92-00-810-806-A
Failure of the Accelerometer 4
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 27-92-00-740-056-A 4. Fault Isolation
Subtask 27-92-00-810-055-A
[Rev.8 from Aug 2018]
2026.04.04 04:27:53 UTC
Failure of the Accelerometer 4
1. Possible Causes
- ACCLRM-4 [12CE4]
wiring of the power supply signal from the accelerometer 4 (12CE4) to the first terminal block
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 27-92-16-000-001 | Removal of the Flight Control Accelerometer |
| AMM 27-92-16-400-001 | Installation of the Flight Control Accelerometer |
| ASM 279224 | |
| AMM 27-96-00-740-001 | BITE Test of the EFCS (Ground Scanning) |
Subtask 27-92-00-740-056-A 4. Fault Isolation
Subtask 27-92-00-810-055-A
A. If the BITE test gives the maintenance message:
ACCLRM 4 12CE4
Subtask 27-92-00-740-057-A ACCLRM 4 12CE4
- replace the ACCLRM-4 [12CE4] , AMM 27-92-16-000-001 and AMM 27-92-16-400-001.
- do a check and repair the
wiring of the power supply signal from the accelerometer 4 (12CE4) to the first terminal block , ASM 279224.
B. Do the test given in Para. 3.