W DOC AIRBUS | TSM A320F

Slats - SFCC TEST Gives the Message PERFORMED WITH FAULT


TASK 27-81-00-810-838-A
Slats - SFCC TEST Gives the Message PERFORMED WITH FAULT


1. Possible Causes
  • SLAT/FLAP CONTR.COMP. [21CV]
  • SLAT/FLAP CONTR.COMP. [22CV]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 27-51-34-000-001
Removal of the SFCC
AMM 27-51-34-400-001
Installation of the SFCC
3. Fault Confirmation
Subtask 27-81-00-710-069-A
A. Test
   (1) If the SLAT SFCC TEST gives the message PERFORMED WITH FAULT, do the fault isolation procedure given in Para. 4.
4. Fault Isolation
Subtask 27-81-00-810-087-A
A. Procedure
   (1) Replace the applicable SLAT/FLAP CONTR.COMP. [21CV] or SLAT/FLAP CONTR.COMP. [22CV] , AMM 27-51-34-000-001 and AMM 27-51-34-400-001.