W DOC AIRBUS | TSM A320F

Slats - SFCC TEST Gives the Message NO FAULTS BUT


TASK 27-81-00-810-835-A
Slats - SFCC TEST Gives the Message NO FAULTS BUT


1. Possible Causes

2. Fault Confirmation
Subtask 27-81-00-710-066-A
A. Test
   (1) Do Para. 4. if the SLATS SFCC TEST gives the message NO FAULTS BUT, with any of the messages that follow:
  • OTHER SFCC ARM SIGNAL NOT TESTED
    or
  • WTB SET
    and/or
  • NO WTB POWER
  • LH WTB SOLENOID S/C (or O/C)
  • RH WTB SOLENOID S/C (or O/C)
  • LH APPU FAULT
  • FPPU FAULT
  • RH APPU FAULT
  • VPS FAULT
3. Fault Isolation
Subtask 27-81-00-810-084-A
A. Procedure
   (1) At the MCDU access the CFDS MENU then LAST LEG REPORT to see if a related fault message was given during normal system operation. The table that follows shows the relationship between the messages given during the SFCC TEST and normal mode, it also gives the related trouble shooting task. Do Para. 4.A. of the applicable task.
NOTE: A fault message given during normal mode will make sure that the fault identified during the SFCC TEST is correct. It will also give the FIN of the defective component.
SFCC TEST MESSAGE
CFDS LAST LEG REPORT MESSAGE
TS TASK IN 27 81 00
OTHER SFCC
ARM SIGNAL
NOT TESTED
SLT 1 (2) NO SFCC 2 (1) DATA
826
NO WTB POWER
SLT 1 (2) C/B 9CV (11CV)
821
LH WTB SOLENOID
S/C (or O/C)
SLT LH WTB BLU (GRN) SOLENOID
35CV OR WIRING TO SLT 1 (2)
822
RH WTB SOLENOID
S/C (or O/C)
SLT RH WTB BLU (GRN) SOLENOID
36CV OR WIRING TO SLT 1 (2)
823
LH APPU FAULT

FPPU FAULT

RH APPU FAULT
LH SLT APPU 31CV OR WIRING TO
SLT 1 (2)
SLT FPPU 28CV OR WIRING TO
SLT 1 (2)
RH SLT APPU 32CV OR WIRING TO
SLT 1 (2)
807

806

807
VPS FAULT
SLT 1 (2) PCU VALVEBLOCK 25CV (26CV) VALVE SENSOR
837
NOTE: The LAST LEG REPORT messages shown are for SFCC 1, the items in ( ) are for SFCC 2.
[Rev.8 from Aug 2018] 2026.04.04 04:27:50 UTC