W DOC AIRBUS | TSM A320F

Slats - Slats Locked at Aircraft Power-Up


TASK 27-81-00-810-834-A
Slats - Slats Locked at Aircraft Power-Up


1. Possible Causes
  • SLAT/FLAP CONTR.COMP. [21CV]
  • SLAT/FLAP CONTR.COMP. [22CV]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 27-51-34-000-001
Removal of the SFCC
AMM 27-51-34-400-001
Installation of the SFCC
AMM 27-80-00-869-004
Reset of the Wing Tip Brake (WTB) of the Slat System on the Ground
AMM 27-81-00-740-002
BITE Test of the Slat and Flap Control Computers (Slat System)
3. Fault Confirmation
Subtask 27-81-00-710-065-A ** ON A/C NOT FOR ALL
A. Not Applicable
4. Fault Isolation
Subtask 27-81-00-810-083-A ** ON A/C NOT FOR ALL
A. Procedure
   (1) Do a reset of the WTBs of the Slat System AMM 27-80-00-869-004.
   (2) If you start the APU with the batteries it is possible that the ECAM warning "F/CTL SLATS LOCKED" is shown.
NOTE: The ECAM warning "F/CTL FLAPS LOCKED" can also show.
     (a) Refer to the TFU 27-51-34-026 and do a check of the SFCC part numbers and serial numbers.
     (b) If applicable, replace the related SFCC SLAT/FLAP CONTR.COMP. [21CV] or SLAT/FLAP CONTR.COMP. [22CV] ,
AMM 27-51-34-000-001 and AMM 27-51-34-400-001.
   (3) If step (2) is not applicable, do a BITE test of SFCC 1 and 2 AMM 27-81-00-740-002:
     (a) If you get a 'NO RESPONSE' message when you select the SFCC menu or if the menu cannot load, replace the related SFCC.
  • Do a check of the part number for the removed SFCC.
  • If the part number is 49-170-11, write the applicable information on the repair tag: NO RESPONSE via MCDU or SFCC MENU CANNOT LOAD.
NOTE: This information is important for the repair shop to do the repair (as given in BAE System vSIL 067).
     (b) If the test gives a fault message, do the trouble shooting procedure related to this message.
[Rev.8 from Aug 2018] 2026.04.04 04:27:50 UTC