Slats - Pin Program Disagree Installation Fault
TASK 27-81-00-810-833-A
Slats - Pin Program Disagree Installation Fault
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 27-81-00-740-067-A
Subtask 27-81-00-810-082-A
[Rev.8 from Aug 2018]
2026.04.04 04:39:13 UTC
Slats - Pin Program Disagree Installation Fault
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 27-51-34-000-001 | Removal of the SFCC |
| AMM 27-51-34-400-001 | Installation of the SFCC |
| ASM 278108 | |
| AMM 31-32-00-860-006 | Procedure to Get Access to the SYSTEM REPORT/TEST F/CTL Page |
Subtask 27-81-00-740-067-A
A. Test
(1) Get access to the SYSTEM REPORT/TEST F/CTL AMM 31-32-00-860-006, press the line key for the applicable SFCC menu, and press the line key for SLT class 3 faults.
(2) If you can get access to the SFCC menu, and SLT class 3 faults, the fault has gone. The system is also serviceable if "PIN PROGRAM DISAGREE INSTALLATION" is shown in class 3 faults, no further action is required. The fault has gone but it has been recorded.
(3) If you cannot get access to the SFCC menu, do the fault isolation procedure.
4. Fault Isolation(1) Get access to the SYSTEM REPORT/TEST F/CTL AMM 31-32-00-860-006, press the line key for the applicable SFCC menu, and press the line key for SLT class 3 faults.
(2) If you can get access to the SFCC menu, and SLT class 3 faults, the fault has gone. The system is also serviceable if "PIN PROGRAM DISAGREE INSTALLATION" is shown in class 3 faults, no further action is required. The fault has gone but it has been recorded.
(3) If you cannot get access to the SFCC menu, do the fault isolation procedure.
Subtask 27-81-00-810-082-A
A. Procedure
(a) Interchange the SLAT/FLAP CONTR.COMP. [21CV] with SLAT/FLAP CONTR.COMP. [22CV] .
(b) Do the test in Para. 3. A. (1).
(2) If the fault moves to the other SFCC position:
(a) Put the serviceable SFCC back in its initial position.
(b) Replace the SFCC that has the fault.
(c) Do the test in Para. 3. A. (1).
(3) If the fault does not move to the other SFCC position:
(a) Put the SFCC's back in their initial position.
(b) Do a check of the aircraft wiring at the SFCC slat channel ASM 278108.
(c) Repair any defect found.
(d) Do the test in Para. 3. A. (1).
NOTE: During this procedure when you interchange, remove or install an SFCC, the AMM procedures AMM 27-51-34-000-001 and AMM 27-51-34-400-001 must be used.
(1) If the message "pin prog disagree slt" is shown: (a) Interchange the SLAT/FLAP CONTR.COMP. [21CV] with SLAT/FLAP CONTR.COMP. [22CV] .
(b) Do the test in Para. 3. A. (1).
(2) If the fault moves to the other SFCC position:
(a) Put the serviceable SFCC back in its initial position.
(b) Replace the SFCC that has the fault.
(c) Do the test in Para. 3. A. (1).
(3) If the fault does not move to the other SFCC position:
(a) Put the SFCC's back in their initial position.
(b) Do a check of the aircraft wiring at the SFCC slat channel ASM 278108.
(c) Repair any defect found.
(d) Do the test in Para. 3. A. (1).