SLT Channel No Cross Talk Between SFCC1 and SFFC2. Loss of Cross Computer Link or Faulty Data
TASK 27-81-00-810-826-A
SLT Channel No Cross Talk Between SFCC1 and SFFC2. Loss of Cross Computer Link or Faulty Data
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 27-81-00-865-059-A
Subtask 27-81-00-810-075-A
[Rev.8 from Aug 2018]
2026.04.04 04:27:49 UTC
SLT Channel No Cross Talk Between SFCC1 and SFFC2. Loss of Cross Computer Link or Faulty Data
NOTE: If the SFCC identified as sending NO DATA is under MMEL or failed, this procedure is not applicable. This fault is a consequence of the failure or MMEL condition.
1. Possible Causes2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 27-51-34-000-001 | Removal of the SFCC |
| AMM 27-51-34-400-001 | Installation of the SFCC |
| ASM 278108 | |
| AMM 27-84-00-710-001 | Operational Test of the Slat System |
| AMM 31-32-00-860-006 | Procedure to Get Access to the SYSTEM REPORT/TEST F/CTL Page |
Subtask 27-81-00-865-059-A
A. Table of the circuit breakers used in this procedure:
Subtask 27-81-00-710-059-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | FLIGHT CONTROLS/SLT/CTL AND MONG/SYS1 | 5CV | B06 |
| 121VU | FLIGHT CONTROLS/SLT/CTL/SYS2 | 7CV | R21 |
B. SFCC Reset and Initialization
(1) At the circuit breakers:
(a) Open the circuit breakers.
(b) Wait for 3 seconds and close the circuit breakers.
(c) Wait for 60 seconds and do the next step.
(2) At the MCDU set the SYSTEM REPORT/TEST FLT CTL page AMM 31-32-00-860-006:
(a) Set the page for the SFCC related to the slat channel which reported the loss of data.
(b) At the applicable SFCC1 (or SFCC2) SYSTEM STATUS SLAT page:
4. Fault Isolation(1) At the circuit breakers:
(a) Open the circuit breakers.
(b) Wait for 3 seconds and close the circuit breakers.
(c) Wait for 60 seconds and do the next step.
(2) At the MCDU set the SYSTEM REPORT/TEST FLT CTL page AMM 31-32-00-860-006:
(a) Set the page for the SFCC related to the slat channel which reported the loss of data.
(b) At the applicable SFCC1 (or SFCC2) SYSTEM STATUS SLAT page:
- if the message SLT1 NO SFCC2 DATA (or SLT2 NO SFCC1 DATA) is shown, do the fault isolation procedure given in Para 4.A.
- if a different message is shown, do the trouble shooting procedure related to this message.
- if no message is shown , no further maintenance action is necessary.
Subtask 27-81-00-810-075-A
A. Procedure
(1) Interchange SFCC1 with SFCC2
AMM 27-51-34-000-001 and AMM 27-51-34-400-001.
(2) Do the test given in Para. 3.B.(2):
(a) Make sure that you install the serviceable SFCC to its initial position.
(b) If the fault continues, do the next step.
(4) Replace the opposite SFCC to that replaced in step (3):
(6) Do the operational test of the slat system AMM 27-84-00-710-001.
(1) Interchange SFCC1 with SFCC2
AMM 27-51-34-000-001 and AMM 27-51-34-400-001.
(2) Do the test given in Para. 3.B.(2):
- if the message stays in the same system, do step (5)
- if the message moves to the opposite system, do the next step.
(a) Make sure that you install the serviceable SFCC to its initial position.
(b) If the fault continues, do the next step.
(4) Replace the opposite SFCC to that replaced in step (3):
- if the fault continues, do the next step.
- Install the SFCCs to their initial positions.
(6) Do the operational test of the slat system AMM 27-84-00-710-001.