SFCC 1 SLT 1 no ADIRU 2 Data or SFCC 2 SLT 2 no ADIRU 2 Data
TASK 27-81-00-810-825-A
SFCC 1 SLT 1 no ADIRU 2 Data or SFCC 2 SLT 2 no ADIRU 2 Data
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 27-81-00-740-063-A
Subtask 27-81-00-810-074-A
[Rev.8 from Aug 2018]
2026.04.04 04:27:49 UTC
SFCC 1 SLT 1 no ADIRU 2 Data or SFCC 2 SLT 2 no ADIRU 2 Data
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 27-51-34-000-001 | Removal of the SFCC |
| AMM 27-51-34-400-001 | Installation of the SFCC |
| ASM 278108 | |
| AMM 31-32-00-860-006 | Procedure to Get Access to the SYSTEM REPORT/TEST F/CTL Page |
| AMM 34-12-34-000-001 | Removal of the ADIRU |
| AMM 34-12-34-400-001 | Installation of the ADIRU |
Subtask 27-81-00-740-063-A
A. Test
(1) At the MCDU aet the MENU MODE and get access to the SYSTEM REPORT/TEST F/CTL page. AMM 31-32-00-860-006.
(a) Get access to the SFCC 1 (2) SYSTEM DATA SLAT page and push the line key adjacent to the ARINC 429 INPUT STATUS indication:
4. Fault Isolation(1) At the MCDU aet the MENU MODE and get access to the SYSTEM REPORT/TEST F/CTL page. AMM 31-32-00-860-006.
(a) Get access to the SFCC 1 (2) SYSTEM DATA SLAT page and push the line key adjacent to the ARINC 429 INPUT STATUS indication:
- if the ARINC input status shows ADIRU 2 LABEL *** NO DATA, do the Fault Isolation Procedure.
NOTE: Additional information on the ARINC 429 INPUT STATUS page can be found in Page Block 301.
Subtask 27-81-00-810-074-A
A. Procedure
(1) Interchange SFCC 1 with SFCC 2 AMM 27-51-34-000-001 AMM 27-51-34-400-001.
(a) Do the test given in Para. 3.A.
(b) If the fault moves with the SFCC 1(2):
1 Install the serviceable SFCC to its initial position.
2 Replace the defective SLAT/FLAP CONTR.COMP. [21CV] or SLAT/FLAP CONTR.COMP. [22CV] .
(c) If the fault does not move to the other SFCC:
1 Install the SFCCs to their initial positions.
2 Do the next step.
(d) If the fault continues, replace the ADIRU-2 [1FP2]
AMM 34-12-34-000-001 and AMM 34-12-34-400-001.
(2) Do the test given in Para. 3.A.
(4) Do the test given in Para. 3.A.
(1) Interchange SFCC 1 with SFCC 2 AMM 27-51-34-000-001 AMM 27-51-34-400-001.
(a) Do the test given in Para. 3.A.
(b) If the fault moves with the SFCC 1(2):
1 Install the serviceable SFCC to its initial position.
2 Replace the defective SLAT/FLAP CONTR.COMP. [21CV] or SLAT/FLAP CONTR.COMP. [22CV] .
(c) If the fault does not move to the other SFCC:
1 Install the SFCCs to their initial positions.
2 Do the next step.
(d) If the fault continues, replace the ADIRU-2 [1FP2]
AMM 34-12-34-000-001 and AMM 34-12-34-400-001.
(2) Do the test given in Para. 3.A.
- if the fault continues, do the next step.
(4) Do the test given in Para. 3.A.