SFCC 1 (2) or SLT PPU Power Fault. SFCC Generated SLT Power Fault


TASK 27-81-00-810-808-A
SFCC 1 (2) or SLT PPU Power Fault. SFCC Generated SLT Power Fault


1. Possible Causes
  • SLAT/FLAP CONTR.COMP. [21CV]
  • SLAT/FLAP CONTR.COMP. [22CV]
  • A/C wiring/interface between SFCC 1 (2) and all PPUs.
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 27-51-34-000-001
Removal of the SFCC
AMM 27-51-34-400-001
Installation of the SFCC
AMM 27-81-00-740-002
BITE Test of the Slat and Flap Control Computers (Slat System)
ASM 278106
ASM 278107
3. Fault Confirmation
Subtask 27-81-00-740-052-A
A. SFCC System Excitation Power Test
   (1) Do a BITE test on the SFCC 1 (2) AMM 27-81-00-740-002. The fault data 'PPU excitation power short circuit' shows.
   (2) Do the fault isolation.
4. Fault Isolation
Subtask 27-81-00-810-057-A
A. Procedure
   (1) Swap SFCC 1 and SFCC 2
AMM 27-51-34-000-001 AMM 27-51-34-400-001.
     (a) Do the BITE test which in given in Para. Fault Confirmation.
     (b) If the fault moves with SFCC 1(2):
       1 Install the serviceable SFCC to its initial position.
       2 Replace the defective SLAT/FLAP CONTR.COMP. [21CV] or SLAT/FLAP CONTR.COMP. [22CV] .
     (c) If the fault does not move to the other SFCC:
       1 Install the SFCCs to their initial positions.
       2 Do the next step.
   (2) Do the BITE test of the applicable SFCC.
     (a) If the fault continues, do a check of the A/C wiring/interface between SFCC 1 (2) and all PPUs. ASM 278106 ASM 278107
     (b) If there is a wiring/interface fault, do the repair.
   (3) Do the BITE test again.
5. Close-up
Subtask 27-81-00-942-058-A
A. Remove the ground support and maintenance equipment, the special and standard tools and all other items.
Subtask 27-81-00-860-059-A
B. Put the aircraft back to its initial configuration.