SFCC - Slat PCU Valveblock Fault
TASK 27-81-00-810-801-A
SFCC - Slat PCU Valveblock Fault
1. Possible Causes
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Fault Confirmation
Subtask 27-81-00-710-050-A
Subtask 27-81-00-810-050-A
Subtask 27-81-00-942-050-A
[Rev.8 from Aug 2018]
2026.04.04 04:39:16 UTC
SFCC - Slat PCU Valveblock Fault
1. Possible Causes
- solenoid valve
- SLAT/FLAP CONTR.COMP. [21CV]
- SLAT/FLAP CONTR.COMP. [22CV]
- valve block filters
- VALVE BLOCK SLAT 1 [25CV]
- VALVE BLOCK SLAT 2 [26CV]
- aircraft wiring
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | MEGOHMMETER 100 MOHMS - MEASURING VOLTAGE 45 VDC |
| No specific | 1 | MULTIMETER - STANDARD |
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 27-81-00-810-837-A | Slats - SFCC 1 (2) Gives PCU Valveblock 25CV (26CV) Valve Sensor Message |
| AMM 27-51-34-000-001 | Removal of the SFCC |
| AMM 27-51-34-400-001 | Installation of the SFCC |
| AMM 27-80-00-866-004 | Extending the Slats on the Ground |
| AMM 27-80-00-866-005 | Retracting the Slats on the Ground |
| ASM 278102 | |
| ASM 278103 | |
| AMM 27-84-53-000-001 | Removal of the Valve Blocks of the Power Control Unit (Slat) |
| AMM 27-84-53-000-002 | Removal of the Solenoid Valves of the Power Control Unit (Slat) |
| AMM 27-84-53-000-003 | Removal of the Filters of the Valve Blocks |
| AMM 27-84-53-400-001 | Installation of the Valve Blocks of the Power Control Unit (Slat) |
| AMM 27-84-53-400-002 | Installation of the Solenoid Valves of the Power Control Unit (Slat) |
| AMM 27-84-53-400-003 | Installation of the Filters of the Valve Blocks |
| AMM 31-32-00-860-006 | Procedure to Get Access to the SYSTEM REPORT/TEST F/CTL Page |
Subtask 27-81-00-710-050-A
A. Test
(1) Make sure that the Post Flight Report does not show any hydraulic system faults.
(2) Move the slats AMM 27-80-00-866-004 and AMM 27-80-00-866-005.
(a) Examine the SFCC, SLT ON GROUND FAULTS page for a PCU valve block message.
(3) If a valve block message is shown, or the A/C has had this fault before, do the fault isolation procedure.
(4) If the fault message SLT 1 (2) PCU VALVEBLOCK 25CV (26CV) VALVE SENSOR 27-84-53 is shown, do TSM Task (Ref. TSM TASK 27-81-00-810-837).
4. Fault Isolation(1) Make sure that the Post Flight Report does not show any hydraulic system faults.
(2) Move the slats AMM 27-80-00-866-004 and AMM 27-80-00-866-005.
(a) Examine the SFCC, SLT ON GROUND FAULTS page for a PCU valve block message.
(3) If a valve block message is shown, or the A/C has had this fault before, do the fault isolation procedure.
(4) If the fault message SLT 1 (2) PCU VALVEBLOCK 25CV (26CV) VALVE SENSOR 27-84-53 is shown, do TSM Task (Ref. TSM TASK 27-81-00-810-837).
Subtask 27-81-00-810-050-A
A. Procedure
(a) Get access to the electrical connector on each valve block AMM 27-84-53-000-001.
1 At the connector receptacle on each valve block, use a MULTIMETER - STANDARD to measure the resistance values of the extend and retract solenoids ASM 278102 or ASM 278103:
5 Supply a test signal for 5 seconds and then read the resistance value shown:
AMM 27-84-53-000-002 and AMM 27-84-53-400-002.
(a) If the fault continues, do the next step.
(4) Interchange the SFCC1 and SFCC2 AMM 27-51-34-000-001 and AMM 27-51-34-400-001.
(a) Do the test in Para. 3.A.(2):
AMM 27-51-34-000-001 and AMM 27-51-34-400-001.
(a) Do the test in Para. 3.A.(2):
(a) Do the test in Para. 3.A.(2). Operate the slats many times during the test, to bleed the air from the system:
(a) Do the test in Para. 3.A.(2).
(9) At the MCDU get access to the SFCC SYSTEM STATUS page and make sure that the message NO FAULTS is shown AMM 31-32-00-860-006.
5. Close-upCAUTION:
MAKE SURE THAT YOU DO NOT CAUSE A SHORT CIRCUIT IN THE WIRING TO THE SOLENOID VALVES. A SHORT CIRCUIT CAN CAUSE DAMAGE TO THE SFCC(S).
(1) Do a check of the PLR for SLT1 (2) PCU VALVEBLOCK 25CV (26CV) VALVE SENSOR 27-84-53 message. If this message is shown, do TSM Task (Ref. TSM TASK 27-81-00-810-837). NOTE: This message is not a CFDS Normal Mode message and is only shown in SFCC reports.
(2) Do a check of the circuit resistance and the circuit isolation of the extend and retract solenoids on each slat system PCU valve block (25CV, 26CV) as follows: (a) Get access to the electrical connector on each valve block AMM 27-84-53-000-001.
1 At the connector receptacle on each valve block, use a MULTIMETER - STANDARD to measure the resistance values of the extend and retract solenoids ASM 278102 or ASM 278103:
- for the extend solenoid measure between pins H and J
- for the retract solenoid, measure between pins T and U.
- for solenoid valves with Part No. 667C0000-02, between 71 Ohms and 84 Ohms.
- for solenoid valves with Part No. 903A0000-01, between 53 Ohms and 60 Ohms.
- for solenoid valves with Part No. 1106A0000-01 or 1111A0000-01, between 53 Ohms and 60 Ohms.
- for solenoid valves with Part No. 5751A0000-01, between 53 Ohms and 60 Ohms.
- for the extend solenoid connect the pins H and J together
- for the retract solenoid connect the pins T and U together.
5 Supply a test signal for 5 seconds and then read the resistance value shown:
- the resistance value must be more than 100 Megohms.
- are OK, do step (4)
- are not OK, do the next step.
AMM 27-84-53-000-002 and AMM 27-84-53-400-002.
(a) If the fault continues, do the next step.
(4) Interchange the SFCC1 and SFCC2 AMM 27-51-34-000-001 and AMM 27-51-34-400-001.
(a) Do the test in Para. 3.A.(2):
- if the fault stays in the same system, do step (6)
- if the fault moves to the other system, do the next step.
AMM 27-51-34-000-001 and AMM 27-51-34-400-001.
(a) Do the test in Para. 3.A.(2):
- if the fault continues, do the next step.
(a) Do the test in Para. 3.A.(2). Operate the slats many times during the test, to bleed the air from the system:
- if the fault continues, do the next step.
- if the fault continues, do the next step.
(a) Do the test in Para. 3.A.(2).
(9) At the MCDU get access to the SFCC SYSTEM STATUS page and make sure that the message NO FAULTS is shown AMM 31-32-00-860-006.
NOTE: More data on the SYSTEM STATUS page can be found in Page Block 301.
Subtask 27-81-00-942-050-A
A. Remove the ground support and maintenance equipment, the special and standard tools and all other items.
Subtask 27-81-00-860-050-A B. Put the aircraft back to its initial configuration.