Incorrect Position of the Right Spoiler 5
TASK 27-60-00-810-849-A
Incorrect Position of the Right Spoiler 5
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 27-60-00-700-130-A
Subtask 27-60-00-810-098-B
[Rev.8 from Aug 2018]
2026.04.04 04:27:46 UTC
Incorrect Position of the Right Spoiler 5
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 27-60-00-866-002 | Extension-Retraction of the Spoilers for Maintenance |
| AMM 27-64-52-000-004 | Removal of the Spoiler Servo-Control |
| AMM 27-64-52-400-004 | Installation of the Spoiler Servo-Control |
| ASM 279403 | |
| AWM 279419 | |
| AWM 279420 | |
| AMM 27-94-34-000-001 | Removal of the SEC |
| AMM 27-94-34-400-001 | Installation of the SEC |
| AMM 27-96-00-710-020 | Operational Test of the Side Stick Assembly (Activation for the BITE Test) |
| AMM 27-96-00-740-001 | BITE Test of the EFCS (Ground Scanning) |
Subtask 27-60-00-700-130-A
A. Test
(1) Do the operational test of the side stick assembly (activation for the BITE test) AMM 27-96-00-710-020.
(2) Do the BITE test of the EFCS (Ground Scanning) AMM 27-96-00-740-001.
4. Fault Isolation(1) Do the operational test of the side stick assembly (activation for the BITE test) AMM 27-96-00-710-020.
(2) Do the BITE test of the EFCS (Ground Scanning) AMM 27-96-00-740-001.
Subtask 27-60-00-810-098-B
A. If the BITE test gives the maintenance message:
R SPLR5 POS ERROR 31CE10
(1) Make sure that the maintenance device of the spoiler servocontrol is in " O " position AMM 27-60-00-866-002.
(2) If the fault continues:
(a) Do a check of the wiring of the ANI 2-7 signal from the SEC 2 (1CE2) MON part to COM part, ASM 279403, AWM 279420
Subtask 27-60-00-700-131-A R SPLR5 POS ERROR 31CE10
(1) Make sure that the maintenance device of the spoiler servocontrol is in " O " position AMM 27-60-00-866-002.
(2) If the fault continues:
- replace the SEC-2 [1CE2] , AMM 27-94-34-000-001 and AMM 27-94-34-400-001.
- replace the SERVO CTL-SPLR5, R G [31CE10] , AMM 27-64-52-000-004 and AMM 27-64-52-400-004.
(a) Do a check of the wiring of the ANI 2-7 signal from the SEC 2 (1CE2) MON part to COM part, ASM 279403, AWM 279420
- if the wiring is correct, do the Para. (b)
- if the wiring is not correct, repair it.
- if the wiring is correct, do the Para. (c)
- if the wiring is not correct, repair it.
B. Do the tests given in Para. 3.