Loss of the Right Spoiler 5 Position Signal for the SEC 2
TASK 27-60-00-810-844-A
Loss of the Right Spoiler 5 Position Signal for the SEC 2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 27-60-00-700-120-A
Subtask 27-60-00-810-093-B
[Rev.8 from Aug 2018]
2026.04.04 04:27:46 UTC
Loss of the Right Spoiler 5 Position Signal for the SEC 2
1. Possible Causes
- SEC-2 [1CE2]
wiring of the ANI 2-7 signal from the SEC 2 (1CE2) to the first terminal block
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 279403 | |
| AMM 27-94-34-000-001 | Removal of the SEC |
| AMM 27-94-34-400-001 | Installation of the SEC |
| AMM 27-96-00-710-020 | Operational Test of the Side Stick Assembly (Activation for the BITE Test) |
| AMM 27-96-00-740-001 | BITE Test of the EFCS (Ground Scanning) |
Subtask 27-60-00-700-120-A
A. Test
(1) Do the operational test of the side stick assembly (activation for the BITE test) AMM 27-96-00-710-020.
(2) Do the BITE test of the EFCS (Ground Scanning) AMM 27-96-00-740-001.
4. Fault Isolation(1) Do the operational test of the side stick assembly (activation for the BITE test) AMM 27-96-00-710-020.
(2) Do the BITE test of the EFCS (Ground Scanning) AMM 27-96-00-740-001.
Subtask 27-60-00-810-093-B
A. If the BITE test gives the maintenance message:
SEC2 COM OR WIRING FROM R SPLR5 POS XDCR 31CE10
or
SEC2 MON OR WIRING FROM R SPLR5 POS XDCR 31CE10
Subtask 27-60-00-700-121-A SEC2 COM OR WIRING FROM R SPLR5 POS XDCR 31CE10
or
SEC2 MON OR WIRING FROM R SPLR5 POS XDCR 31CE10
- replace the SEC-2 [1CE2] , AMM 27-94-34-000-001 and AMM 27-94-34-400-001.
- do a check and repair the
wiring of the ANI 2-7 signal from the SEC 2 (1CE2) to the first terminal block COM part or MON part as shown in the maintenance message ASM 279403.
B. Do the tests given in Para. 3.