Loss of the Right Spoiler 4 Servo Valve Signal for the SEC 1
TASK 27-60-00-810-839-A
Loss of the Right Spoiler 4 Servo Valve Signal for the SEC 1
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 27-60-00-700-110-A
Subtask 27-60-00-810-088-B
[Rev.8 from Aug 2018]
2026.04.04 04:27:45 UTC
Loss of the Right Spoiler 4 Servo Valve Signal for the SEC 1
1. Possible Causes
- SEC-1 [1CE1]
- servovalve
wiring of the SV signal from the servo control (31CE8) to SEC 1 (1CE1)
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 27-64-51-000-002 | Removal of the Servo-Valve from the Spoiler Servo-Control |
| AMM 27-64-51-400-002 | Installation of the Servo-Valve on the Spoiler Servo-Control |
| ASM 279402 | |
| AMM 27-94-34-000-001 | Removal of the SEC |
| AMM 27-94-34-400-001 | Installation of the SEC |
| AMM 27-96-00-710-020 | Operational Test of the Side Stick Assembly (Activation for the BITE Test) |
| AMM 27-96-00-740-001 | BITE Test of the EFCS (Ground Scanning) |
Subtask 27-60-00-700-110-A
A. Test
(1) Do the operational test of the side stick assembly (activation for the BITE test) AMM 27-96-00-710-020.
(2) Do the BITE test of the EFCS (Ground Scanning) AMM 27-96-00-740-001.
4. Fault Isolation(1) Do the operational test of the side stick assembly (activation for the BITE test) AMM 27-96-00-710-020.
(2) Do the BITE test of the EFCS (Ground Scanning) AMM 27-96-00-740-001.
Subtask 27-60-00-810-088-B
A. If the BITE test gives the maintenance message:
R SPLR4 SERVO VLV 31CE8 OR OUTPUT FROM SEC1
Subtask 27-60-00-700-111-A R SPLR4 SERVO VLV 31CE8 OR OUTPUT FROM SEC1
- Replace the SEC-1 [1CE1] AMM 27-94-34-000-001 and AMM 27-94-34-400-001.
- Replace the servovalve related to the maintenance message AMM 27-64-51-000-002 and AMM 27-64-51-400-002.
NOTE: The resistance must be 500 ohms +/- 10 %.
(2) If the fault continues:- Do a check and repair the
wiring of the SV signal from the servo control (31CE8) to SEC 1 (1CE1) , ASM 279402.
B. Do the tests given in Para. 3.