W DOC AIRBUS | TSM A320F

Loss of the Right Spoiler 4 Position Signal for the SEC 1


TASK 27-60-00-810-836-A
Loss of the Right Spoiler 4 Position Signal for the SEC 1


1. Possible Causes
  • SEC-1 [1CE1]
  • wiring of the ANI 2-7 signal from the SEC 1 (1CE1) to the first terminal block
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 279402
AMM 27-94-34-000-001
Removal of the SEC
AMM 27-94-34-400-001
Installation of the SEC
AMM 27-96-00-710-020
Operational Test of the Side Stick Assembly (Activation for the BITE Test)
AMM 27-96-00-740-001
BITE Test of the EFCS (Ground Scanning)
3. Fault Confirmation
Subtask 27-60-00-700-104-A
A. Test
   (1) Do the operational test of the side stick assembly (activation for the BITE test) AMM 27-96-00-710-020.
   (2) Do the BITE test of the EFCS (Ground Scanning) AMM 27-96-00-740-001.
4. Fault Isolation
Subtask 27-60-00-810-085-B
A. If the BITE test gives the maintenance message:
SEC1 COM OR WIRING FROM R SPLR4 POS XDCR 31CE8
or
SEC1 MON OR WIRING FROM R SPLR4 POS XDCR 31CE8
   (1) If the fault continues:
  • do a check and repair the wiring of the ANI 2-7 signal from the SEC 1 (1CE1) to the first terminal block COM part or MON part as shown in the maintenance message ASM 279402.
Subtask 27-60-00-700-105-A
B. Do the tests given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:27:44 UTC