Loss of the Right Spoiler 4 Position Signal for the SEC 1
TASK 27-60-00-810-836-A
Loss of the Right Spoiler 4 Position Signal for the SEC 1
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 27-60-00-700-104-A
Subtask 27-60-00-810-085-B
[Rev.8 from Aug 2018]
2026.04.04 04:27:44 UTC
Loss of the Right Spoiler 4 Position Signal for the SEC 1
1. Possible Causes
- SEC-1 [1CE1]
wiring of the ANI 2-7 signal from the SEC 1 (1CE1) to the first terminal block
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 279402 | |
| AMM 27-94-34-000-001 | Removal of the SEC |
| AMM 27-94-34-400-001 | Installation of the SEC |
| AMM 27-96-00-710-020 | Operational Test of the Side Stick Assembly (Activation for the BITE Test) |
| AMM 27-96-00-740-001 | BITE Test of the EFCS (Ground Scanning) |
Subtask 27-60-00-700-104-A
A. Test
(1) Do the operational test of the side stick assembly (activation for the BITE test) AMM 27-96-00-710-020.
(2) Do the BITE test of the EFCS (Ground Scanning) AMM 27-96-00-740-001.
4. Fault Isolation(1) Do the operational test of the side stick assembly (activation for the BITE test) AMM 27-96-00-710-020.
(2) Do the BITE test of the EFCS (Ground Scanning) AMM 27-96-00-740-001.
Subtask 27-60-00-810-085-B
A. If the BITE test gives the maintenance message:
SEC1 COM OR WIRING FROM R SPLR4 POS XDCR 31CE8
or
SEC1 MON OR WIRING FROM R SPLR4 POS XDCR 31CE8
Subtask 27-60-00-700-105-A SEC1 COM OR WIRING FROM R SPLR4 POS XDCR 31CE8
or
SEC1 MON OR WIRING FROM R SPLR4 POS XDCR 31CE8
- replace the SEC-1 [1CE1] , AMM 27-94-34-000-001 and AMM 27-94-34-400-001.
- do a check and repair the
wiring of the ANI 2-7 signal from the SEC 1 (1CE1) to the first terminal block COM part or MON part as shown in the maintenance message ASM 279402.
B. Do the tests given in Para. 3.