Loss of the Right Spoiler 2 Servo Valve Signal for the SEC 3
TASK 27-60-00-810-823-A
Loss of the Right Spoiler 2 Servo Valve Signal for the SEC 3
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 27-60-00-700-078-A
Subtask 27-60-00-810-072-A
[Rev.8 from Aug 2018]
2026.04.04 04:27:43 UTC
Loss of the Right Spoiler 2 Servo Valve Signal for the SEC 3
1. Possible Causes
- SEC-3 [1CE3]
- servovalve
wiring of the SV signal from the servo control (31CE4) to the SEC 3 (1CE3)
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 27-64-51-000-002 | Removal of the Servo-Valve from the Spoiler Servo-Control |
| AMM 27-64-51-400-002 | Installation of the Servo-Valve on the Spoiler Servo-Control |
| ASM 279404 | |
| AMM 27-94-34-000-001 | Removal of the SEC |
| AMM 27-94-34-400-001 | Installation of the SEC |
| AMM 27-96-00-710-020 | Operational Test of the Side Stick Assembly (Activation for the BITE Test) |
| AMM 27-96-00-740-001 | BITE Test of the EFCS (Ground Scanning) |
Subtask 27-60-00-700-078-A
A. Test
(1) Do the operational test of the side stick assembly (activation for BITE test) AMM 27-96-00-710-020.
(2) Do the BITE test of the EFCS (Ground scanning) AMM 27-96-00-740-001.
4. Fault Isolation(1) Do the operational test of the side stick assembly (activation for BITE test) AMM 27-96-00-710-020.
(2) Do the BITE test of the EFCS (Ground scanning) AMM 27-96-00-740-001.
Subtask 27-60-00-810-072-A
A. If the BITE test gives the maintenance message:
R SPLR 2 SERVO VLV 31CE4 OR OUTPUT FROM SEC 3:
Subtask 27-60-00-700-079-A R SPLR 2 SERVO VLV 31CE4 OR OUTPUT FROM SEC 3:
- Replace the SEC-3 [1CE3] , AMM 27-94-34-000-001 and AMM 27-94-34-400-001.
- Replace the servovalve related to the maintenance message, AMM 27-64-51-000-002 and AMM 27-64-51-400-002.
NOTE: The resistance must be 500 ohms +/- 10 %.
(2) If the fault continues: - Do a check and repair the
wiring of the SV signal from the servo control (31CE4) to the SEC 3 (1CE3) , ASM 279404.
B. Do the tests given in Para. 3.