Loss of the Right Spoiler 1 Servo Valve Signal for the SEC 3


TASK 27-60-00-810-815-A
Loss of the Right Spoiler 1 Servo Valve Signal for the SEC 3


1. Possible Causes
  • SEC-3 [1CE3]
  • servovalve
  • wiring of the SV signal from the servo control (31CE2) to the SEC 3 (1CE3)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 27-64-51-000-002
Removal of the Servo-Valve from the Spoiler Servo-Control
AMM 27-64-51-400-002
Installation of the Servo-Valve on the Spoiler Servo-Control
ASM 279404
AMM 27-94-34-000-001
Removal of the SEC
AMM 27-94-34-400-001
Installation of the SEC
AMM 27-96-00-740-001
BITE Test of the EFCS (Ground Scanning)
AMM 29-10-00-863-001
Pressurize the Green Hydraulic System with a Hydraulic Ground Power-Cart
AMM 29-10-00-864-001
Depressurize the Green Hydraulic System
3. Fault Confirmation
Subtask 27-60-00-860-060-A
A. Job Set-Up
   (1) Pressurize the Green hydraulic system AMM 29-10-00-863-001.
   (2) Pull the speedbrake control lever (7CE) up to the armed position on the panel 11VU.
Subtask 27-60-00-740-060-A
B. Test
   (1) Do the BITE test of the EFCS (Ground Scanning) AMM 27-96-00-740-001.
Subtask 27-60-00-860-061-A
C. Put the aircraft back to its initial configuration.
   (1) Depressurize the Green hydraulic system AMM 29-10-00-864-001.
   (2) Disarm the speedbrake control lever (7CE) on the panel 11VU.
4. Fault Isolation
Subtask 27-60-00-810-064-A
A. If the BITE test gives the maintenance message:
R SPLR 1 SERVO VLV 31CE2 OR OUTPUT FROM SEC 3
   (1) If the fault continues:
NOTE: The resistance must be 500 ohms +/- 10 %.
   (2) If the fault continues:
  • Do a check and repair the wiring of the SV signal from the servo control (31CE2) to the SEC 3 (1CE3), ASM 279404.
Subtask 27-60-00-740-061-A
B. Do the test given in Para. 3.