Loss of the Speedbrake Control Signal for the SEC 3
TASK 27-60-00-810-802-A
Loss of the Speedbrake Control Signal for the SEC 3
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 27-60-00-700-052-A
Subtask 27-60-00-810-051-B
[Rev.8 from Aug 2018]
2026.04.04 04:27:41 UTC
Loss of the Speedbrake Control Signal for the SEC 3
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 27-92-14-000-001 | Removal of the Speedbrake Control Transducer-Unit |
| AMM 27-92-14-400-001 | Installation of the Speedbrake Control Transducer-Unit |
| ASM 279219 | |
| AMM 27-94-00-710-001 | Operational Test of the Spoiler Elevator Computer 3 (SEC 3) |
| AMM 27-94-34-000-001 | Removal of the SEC |
| AMM 27-94-34-400-001 | Installation of the SEC |
| AMM 27-96-00-740-001 | BITE Test of the EFCS (Ground Scanning) |
Subtask 27-60-00-700-052-A
A. Test
(1) Do the operational test of the spoiler elevator computer 3 AMM 27-94-00-710-001.
(2) Do the BITE test of the EFCS (Ground Scanning) AMM 27-96-00-740-001.
4. Fault Isolation(1) Do the operational test of the spoiler elevator computer 3 AMM 27-94-00-710-001.
(2) Do the BITE test of the EFCS (Ground Scanning) AMM 27-96-00-740-001.
Subtask 27-60-00-810-051-B
A. If the BITE test gives the maintenance message:
SEC3 OR INPUT OF SPBK CTL XDCR UNIT 7CE
Subtask 27-60-00-700-053-A SEC3 OR INPUT OF SPBK CTL XDCR UNIT 7CE
- replace the SEC-3 [1CE3] , AMM 27-94-34-000-001 and AMM 27-94-34-400-001.
- replace the XDCR UNIT-SPD BRK CTL [7CE] , AMM 27-92-14-000-001 and AMM 27-92-14-400-001.
- do a check and repair the
wiring from the SEC 3 (1CE3) to the transducer unit (7CE) ASM 279219.
B. Do the operational test and the BITE test given in Para. 3.